8. coMMIssIonIng
You receive a fully assembled "stationary busbar bending and hole-punching unit" as well as detailed
operating instructions.
• On receiving the goods, check them for possible transport damage and the delivery for completeness.
• In the event of problems, contact the manufacturer or your vendor without delay.
• In any case, read the complete operating instructions as well as all supplied documents before
commissioning.
!
caution!
there is a risk of injury when lifting the unit in its packaging or if the lifted unit falls
(total weight approx. 60 kg).
• Please note the maximum weights that may be lifted by persons.
It may be necessary to use lifting gear.
• Do not stand below the lifted unit.
!
caution!
when recommissioning the unit, there is the risk that incorrect storage or missing corrosion
protection can block unit components and so cause dangers.
• Before recommissioning, ensure the smooth running of all components and the correct
function of all safety equipment (see section 11 "Maintenance and inspection").
• Wear your personal protective equipment, in particular gloves and safety work shoes,
also for the transport and installation of the unit (see section 2.4 "Personal protective equipment").
• Ensure that the surface on which the unit is placed is flat and sufficiently stable.
• Inspect the hydraulic hose and the control cable for crushing and any other damage. Never use damaged
hydraulic supply lines or electrical supply cables.
note:
the hydraulic hose and the electrical control cable for the table unit are supplied as set in a
stable safety protection tube. as supplied, the hydraulic hose is filled with hydraulic oil hlP46.
• Inspect the mains cable and plug of the hydraulic pump for damage. Do not use the electro-
hydraulic pump should there be any damage!
• Place the unit secure and stable to ensure a safe positioning of the unit.
• Connect the hydraulic hose to the hydraulic connection (17) and the electrical control cable
to the electrical connection (16) of the unit.
!
caution!
If the unit is operated with a non-approved pump, there is risk of injury caused by bursting
components of the hydraulic circuit.
• ensure that only the electro-hydraulic pump, in conjunction with the unit, as specified in the
technical specifications is deployed.
note:
there is risk of hydraulic oil escaping in the event of a defective valve or when the hydraulic
hose is disconnected under pressure.
•
ensure that the hydraulic system is pressure-free before disconnecting or reinserting the
hydraulic hose.
• Then insert the supply cable of the foot-operated switch in the 4-pin connection (15).
• Before the first use, the sealing screw plug (black) at the tank opening must be replaced with the air
permeable ventilation screw (orange) so that air can flow into the oil tank during work.