background image

 

 

 

Seite 4

 

 

 

 

5.  Komponenten 

/ Components

 

 

 

 

6.  Aufstellung / 

Placement

 

 

 

 

 

(1)  Bedienfeld / 

Operation area

 

(2)  Staubsensor / 

Dust sensor

 

(3)  Frontplatte / 

Front panel

 

(4)  Lufteinsaug / 

Air intake

 

(5)  Tragegriff / 

Carrying handle

 

(6)  Luftausblas / 

Air outlet

 

(7)  Stromkabel / 

power cable 

 

 

 

 

 

 

 

 

 

(1)  Nicht auf anderen Geräten platzieren /

Do not place the 

unit on top of other equipment

 

(2) 

Keine brennbaren Gase oder Flüssigkeiten in der Nähe 

des Gerätes verwenden / 

do not use inflammable gas or 

liquid near the unit 

(3)  Freie Luftzirkulation ermöglichen. Mind. 20 cm Abstand 

links und rechts und 30-60cm Abstand nach oben halten / 

For better performance place the unit min. 20 cm away 
from surroundings and 30-60 cm distance up

 

(4)  Mind. 2 m Abstand zu TV und Radio-Geräten einhalten / 

keep min. 2 m distance to TV and Radio

 

(5) 

Vermeiden Sie Schmutz, Feuchtigkeit und Nässe bei der 
Aufstellung / 

please do not put the unit in a dirty, humid 

or wet place 

(6) 

Stellen Sie das Gerät auf einem geraden, sicheren 

Untergrund auf / 

do not put the unit on a slope or similar 

(7)  Platzieren Sie das Gerät dort, wo die Luftverunreinigung 

am größten ist / 

place the unit near the source of the 

polluted air for more effective results

 

7.  Bedienung 

 

Um den bestmöglichen Nutzen durch den  Luftreiniger zu 

erzielen, richten Sie den Standort und Betrieb 

entsprechend hoher Luftbelastungen aus. 

 

Arbeitsweisen 

 

1. Anschluss des Netzkabels 

Sobald das Netzkabel angeschlossen ist, beginnt das 

Gerät  in der zuletzt gewählten Ventilator-Stufe zu 

arbeiten. 

2. On / Off-Taste  

Durch das Drücken der Power-Taste wird das Gerät ein- 

bzw. ausgeschaltet. 

3. Mode-Taste 

Wählen Sie zwischen manuellem, automatischem oder 

Schlaf-Modus aus. Im Schlafmodus werden die LED-

Anzeigen gedimmt und die kleinste Ventilatorstufe 

eingeschaltet. Im Automatikbetrieb wird entsprechend 

dem durch den Staubsensor aktivierten Ventilatormodus 

(blau – kleine Stufe, gelb – mittlere Stufe, rot – große 

Stufe) gewählt. 

4. Fan Speed-Taste  

Drücken Sie die Taste zur Auswahl der Lüfter-

Geschwindigkeit für den manuellen Betriebsmodus. Die 

LED-Anzeige zeigt „S“ für Schlafmodus, ein Zeichen für 

niedrige, zwei für mittlere und drei für hohe 

Geschwindigkeit. 

 

7. Operation 

 

To make the best use of the air purifier, please place and 

adjust it properly according to air pollution period and 

area.  

 

Method of Operation  

 

1. Connect the power  

Connect the power, the unit will start to work when it is 

plugged in. The initial mode will be the same as it was 

switched off last time. 

2. On/Off Button  

Press the power button, the unit will be switched off/on.  

3. Mode Button 

Choice between manual, automatic and sleep mode. 

Sleep mode will dim the LED and choice the lowest fan 

speed. Automatic mode will choice the fan speed by itself 

concerning the result of the dust sensor (blue – low, 

yellow – medium, red – high speed). 

4. Fan Speed Button  

Press the button for selection of fan speed for the manual 

mode. The LED screen will indicate ”S” for Sleep, one 

sign for low speed, two for medium and three for high.  

 

 

 

 

Содержание ALR400

Страница 1: ...da Luftreiniger ALR400 alfda Air purifier ALR400 BITTE BEACHTEN Vor der Erstinbetriebnahme muss die Folienverpackung des Filtersets entfernt werden Lesen Sie die Bedienungsanweisung hierzu bitte kompl...

Страница 2: ...zeit Vent Stufe 20 m2 50 m3 15 Min 1 20 m2 50 m3 8 Min 4 40 m2 100 m3 20 Min 2 40 m2 100 m3 15 Min 4 60 m2 150 m3 45 Min 1 60 m2 150 m3 20 Min 4 80 m2 200 m3 45 Min 2 80 m2 200 m3 30 Min 4 alfda Air P...

Страница 3: ...Stromaufnahme Stand By 2 Watt Luftleistung min max ca 201 445 m3 h Lautst rke min max ca 34 49 dB A Netto Gewicht ca 12 kg Abmessungen LxBxH 460x270x690 mm Empf Raumgr e max 80 m2 200 m3 2 Cautions c...

Страница 4: ...el angeschlossen ist beginnt das Ger t in der zuletzt gew hlten Ventilator Stufe zu arbeiten 2 On Off Taste Durch das Dr cken der Power Taste wird das Ger t ein bzw ausgeschaltet 3 Mode Taste W hlen S...

Страница 5: ...witched on The initial mode is the same mode as it was used before The external timer is not included in the scope of delivery 8 Self lock button Press the self lock button for 2 seconds to lock all b...

Страница 6: ...ur vacuum cleaner one time a month Clean the dust sensor box carefully in the same way 10 Filter Replacement The standard lifespan of the filters is one year However it will also depend on the duratio...

Страница 7: ...control If your air purifier should still not functioning properly we regret this and ask you to contact the authorized customer service The warranty period is 2 years from date of purchase The guara...

Страница 8: ...lgemeinen Hausm ll ber daf r staatlich vorgesehene Stellen entsorgt werden Dies kann durch R ckgabe beim Kauf eines hnlichen Ger tes oder durch Abgabe bei einer autorisierten Sammelstelle f r die Wied...