4 Operation
Read the instructions carefully and pay special attention to the warnings!
Step 5
Double mechanical shaft seal:
1. Connect the inlet of the flushing liquid correctly.
2. Regulate the water supply correctly.
O: Outlet
I: Inlet
T
max
= 70°C
(158°F)
P
max
LKHUP10-60
= 5 bar
(72.5 psi)
P
max
LKHUP70
= 3 bar
(43.5 psi)
3007-0095
O
I
Step 6
Control:
Reduce the capacity and the power consumption by means of:
-
Throttling the pressure side of the pump.
-
Reducing the impeller diameter.
-
Reducing the speed of the motor.
3007-0018
Throttling!