3 Installation
Read the instructions carefully and pay special attention to the warnings! Always check the pump before operation.
- See pre-use check in section 3.3 Pre-use check. The large pump sizes are very heavy. Alfa Laval therefore recommends the
use of a lifting crane when handling the pump.
3.2
Installation
Step 1
Always read the technical data thoroughly. (See chaper 6 Technical data)
Always use a lifting crane when handling the pump.
Always have the pump electrically connected by authorised personnel. (see the motor instructions).
CAUTION
Alfa Laval cannot be held responsible for incorrect installation.
WARNING
Alfa Laval recommends the installation of lockable repair breaker. If the repair breaker is to be used as an emergency stop,
the colours of the repair breaker must be red and yellow.
CAUTION
The pump does not prevent back flow when intentionally or unintentionally stopped. If back flow can cause any hazardous
situations precautions must be taken e.g. check valve to be installed in the system to prevent the problem described above.
Note
The 3A standard requires minimum clearance between the lowest part of the base, pump, motor or drive and for the floor to
be no less than 4 inch. (100mm)
Step 2
Ensure at least 0.5m (1.6 ft) clearance around the pump.
3007-0094