5 Maintenance
Maintain the valve regularly.
Study the instructions carefully and pay special attention to the warnings!
Always keep spare rubber seals in stock.
Check the valve for smooth operation after service.
5.1
General maintenance
Step 1
Always read the technical data thoroughly.
See chapter 6 Technical data.
Always release compressed air after use.
NOTE
All scrap must be stored/discharged in accordance
with current rules/directives.
Step 2
Never service the valve when it is hot.
Never service the valve with valve and pipelines under pressure.
Burning
danger!
2508-0061
Step 3
Never stick your fingers through the valve ports if the actuator is
supplied with compressed air.
Never touch the moving parts if the actuator is supplied with
compressed air.
Moving parts!
Cutting danger!
2508-0060
Moving parts!
18