background image

Installation and Normal Operation

 (continued) 

Normal Operation 

Cleaning Media 

Use only media compatible with Stainless Steel AISI 316L, PTFE, PEEK and EPDM. Please note that 
PEEK is not resistant to concentrated sulfuric acid. Normal detergents, moderate solutions of acids and 
alkalics will be acceptable. Aggressive chemicals, excessive concentrations of chemicals at elevated 
temperatures, as well as certain hypochlorids should be avoided. If you are in doubt, contact your local 
Alfa Laval Tank Equipment sales office. 
 
 

Temperature 

Max. temperature 140

°

C at steam sterilisation.  

 
 

Pressure 

Please make sure that the connections are correctly mounted before opening of the washing valve. Put 
on pressure gradually in order to avoid hydraulic shocks, which might stress mechanical parts in the 
Toftejorg SaniMega cleaner. Max. pressure is 4.0 bar. 
 
 

After Use Cleaning 

After using the Toftejorg SaniMega, flush the machine with clean water. Cleaning solutions should 
never be allowed to dry or set-up in the system due to possible "salting out" or "scaling" of the cleaning 
ingredient. 
 

Warning

 

Do not touch hot surfaces when working with hot cleaning solutions or steaming. 

Never try to loosen clamps without securing against pressure on the pipe line. 

Instruction Manual, Toftejorg SaniMega 

Page 9  

IM-TE91A590-EN1 

ï

Return to menu

Содержание Toftejorg SaniMega

Страница 1: ...IM TE91A590 EN1 August 2005 Toftejorg SaniMega Instruction Manual Return to menu...

Страница 2: ...ration 9 Maintenance and repair 10 Preventive Maintenance 10 Turbine and Gear Assembly 11 Cleaner Head Assembly 12 Reference List of Parts 13 Rotacheck 14 Installation Guide 14 How to Order Spare Part...

Страница 3: ...nce on the contrary means good performance no unscheduled stops and superior total economy The information in this manual is simple to follow but should you require further assistance our Customer Ser...

Страница 4: ...he Turbine into rotation It then continues downwards to the Cleaner head and out through the slots The rotation of the Turbine is via the Gear transmitted to the Drive shaft which makes the Cleaner he...

Страница 5: ...e length 1 200 or 1 500 mm Min tank opening 72 5 mm Materials Stainless steel AISI 316L PTFE PEEK EPDM Options A non invasive electronic Rotation Sensor to validate speed of the cleaner can be include...

Страница 6: ...cal Data continued Principal dimensions Dimensions in mm Dimensions for Options For welding end 65 99mm For NW100 DIN Union 234 mm Page 6 Instruction Manual Toftejorg SaniMega IM TE91A590 EN1 Return t...

Страница 7: ...Technical Data continued Performance Data Flow Rate Rotating speed Instruction Manual Toftejorg SaniMega Page 7 IM TE91A590 EN1 Return to menu...

Страница 8: ...grinding dust scale and other foreign matter Note The machine shall be installed in accordance with national regulations for safety and other relevant regulations and standards Precautions shall be m...

Страница 9: ...team sterilisation Pressure Please make sure that the connections are correctly mounted before opening of the washing valve Put on pressure gradually in order to avoid hydraulic shocks which might str...

Страница 10: ...manual Never assemble components without previous cleaning This is especially important at all mating surfaces Work in a clear well lighted work area Every 300 500 working hours Inspect the gear turbi...

Страница 11: ...e removed 3 Remove Circlip Pos 11 and pull out the Pinion Pos 1 releasing the Worm wheel pos 2 and Washer Pos 14 4 Remove the Circlip Pos 11 and pull off the Horizontal shaft Pos 12 Reassembly Reassem...

Страница 12: ...el surface 1 Dismount the Clamp ring Inlet connection and Gasket Pos 20 19 and 21 2 Push up the Cleaner head Pos 17 and remove the Lock ring Pos 18 If necessary hold Drive shaft Pos 9 in position when...

Страница 13: ...ft Stainless steel 9 TE12A530 33 1 Drive shaft Stainless steel 10 TE12A507 1 Shaft Stainless steel 11 TE51C202 3 Circlip Stainless steel 12 TE12A513 1 Horizontal shaft Polymer 13 TE51C004 1 Pin Stainl...

Страница 14: ...the relay Technical Data Dimensions 12x12x30 mm Connection electrical 2m PVC cable 2x0 34mm 2 Supply voltage 5 24 V DC Supply voltage Ex approv Max 8 2 V DC Current consumption Magnet sensed 3 mA Curr...

Страница 15: ...r for sensor Polymer 5 TE12A356 1 Magnet complete Working Instructions 1 Remove the Inlet connection Pos 19 page 13 2 Remove Circlip Pos 11 and Gear wheel Pos 4 page 13 3 Fit Magnet Pos 5 in Gear whee...

Страница 16: ...ion Material 3 TE51C017 2 Cylindrical Pin Stainless steel 6 TE20G549 2 Bearing f Turbine shaft Polymer 11 TE51C202 3 Circlip Stainless steel 12 TE12A513 1 Horizontal shaft Polymer 18 TE12A559 1 Lock r...

Страница 17: ...of Machine Serial No Length mm Date No of Working Hours Maintenance Actions Exchanged Parts Remarks Sign 0 Machine put into operation V 94 2 Instruction Manual Toftejorg SaniMega Page 17 IM TE91A590 E...

Страница 18: ...c shock be disregarded Yes No Inlet line flushed before installation of tank cleaner Yes No Working hours before failure hours Cleaning Programme Cleaning media and conc Temperature Time Recirculation...

Страница 19: ...installed in inlet line Yes Mesh size mm No Is tank cleaner flushed with clean water after tank cleaning Yes No Type of Soilage Tank Contents to be removed Name formula concentration of material to be...

Отзывы: