Installation Guide
(continued)
Rotacheck for Toftejorg SaniMega complete TE12A305, Reference List of Parts
Pos.
Ref. No.
Number
Description
Material
1
TE12A555
1
Clamp for sensor
Stainless steel
2
TE51A148
1
Screw
Stainless steel
3 TE51V555
1
Sensor
4
TE12A557
1
Isolator for sensor
Polymer
5 TE12A356
1
Magnet
complete
Working Instructions
1.
Remove the Inlet connection (Pos. 19, page 13)
2.
Remove Circlip (Pos. 11) and Gear wheel (Pos. 4, page 13).
3.
Fit Magnet (Pos. 5) in Gear wheel
4.
Fit Gear wheel with Magnet complete on shaft
5.
Fit Inlet connection
6. Fit pos. 1, 2, 3 and 4 on the Housing. Position of the Sensor is important. It must be fitted on the
right side of tap.
Instruction Manual, Toftejorg SaniMega
Page 15
IM-TE91A590-EN1
ï