Page 14
Instruction manual
TE67X000002150 Ethernet Module
Status and weight transfer using EtherNetIP
IM-TE91K013-EN2
6) Hardware description
(continued)
6.4 RS485 connector (J1)
The green 3 pole connector (J1) at the bottom of the TE67X000002150 Ethernet module contains the
same RS485 bus that is available through the ribbon cable connector (J7), which is normally used for
interfacing load cells. This allows an alternate way of connecting load cells to the TE67X000002150
module. In other applications where no load cells are connected to the TE67X000002150 module, this
connector may be used to interface different equipment to the TE67X000002150 module using RS485
communication.
The 3 pole connector (J1) on the TE67X000002150 Ethernet module has these connections:
J1 CONNECTER
FUNCTION
J1.1
RS485-B (DATA- )
J1.2
RS485-A (DATA+)
J1.3
0 VDC (GNDin)
6.5 RS232 connector (J4)
The small 4 pole connector (J4) at the bottom of the TE67X000002150 Ethernet module contains an
RS232 communication channel. This RS232 channel is used for setup/configuration of the
TE67X000002150 Ethernet module from a PC as described below. Connection to this connector is
made using a special serial cable supplied by Alfa Laval Kolding A/S.
The 4 pole connector (J4) on the TE67X000002150 Ethernet module has these connections:
J4 CONNECTER
FUNCTION
J4.1
RS232-GND (connected to PC- GND)
J4.2
RS232-RXD (connected to PC-TXD)
J4.3
RS232-TXD (connected to PC-RXD)
J4.4
RS232-GND (connected to PC- GND)
6.6 Ethernet connector (J8)
The front panel of the TE67X000002150 Ethernet module is equipped with a standard Ethernet
RJ47 connector for Cat5 cables.
Содержание TE67X000002150
Страница 2: ......