5 Maintenance
Read the instructions carefully. The items refer to the parts list and service kits section.
Handle scrap correctly.
: Relates to the shaft seal.
Step
Step
Step 6
6
6
1. Remove the stationary seal ring (11).
2. Remove the O-ring (12) from back plate (25).
*) Use the tool supplied. Left hand thread!
Step
Step
Step 7
7
7
Flushed
Flushed
Flushed shaft
shaft
shaft seal:
seal:
seal:
1. Remove screws (41) and seal housing (40).
2. Pull out lip seal (43) from the seal housing.
Step
Step
Step 8
8
8
Double
Double
Double mechanical
mechanical
mechanical shaft
shaft
shaft seal:
seal:
seal:
1. Remove screws (41) and seal housing (40a).
2. Remove rotating seal rings (14) and drive ring (52) from
spring (13).
3. Remove O-rings (15) from rotating seal rings (14).
4. LKH-70 to 90: Remove cups (54) from rotating seal rings.
Step
Step
Step 9
9
9
Double
Double
Double mechanical
mechanical
mechanical shaft
shaft
shaft seal:
seal:
seal:
1. Remove stationary seal ring (51) from seal housing (40a).
2. Remove O-ring (50) from stationary seal ring (51).
3. Remove O-ring (44) from seal housing (40a).
Step
Step
Step 10
10
10
1. Remove the complete shaft seal from stub shaft (7).
2. Remove spring (13) and rotating seal ring (14) from the drive
ring (10).
31
Содержание LKH Series
Страница 1: ...ESE00698 EN30 2022 07 Original manual Instruction Manual LKH Centrifugal Pump...
Страница 2: ......
Страница 64: ...7 Parts list and service kits The drawing shows the LKH pump sanitary version 64...
Страница 69: ...69...
Страница 70: ...LKH Shaft seal and service kits If inducer 57 is retrofitted Pump inlet may have to be slightly ground 70...
Страница 72: ...LKH Shaft seal and service kits If inducer 57 is retrofitted Pump inlet may have to be slightly ground 72...
Страница 75: ...75...