5 Maintenance
Maintain the pump with care. Read the instructions carefully and pay special attention to the warnings!
Always keep spare shaft seals and rubber seals in stock.
See separate motor instructions.
Check the pump for smooth operation after service.
Safety
Safety
Safety check
check
check
A visual inspection of adaptor shield and motor fan guard must be carried out every 12 months.
If loss or damage to shield or guard, especially when this leads to deterioration of safety performance, it shall be replaced.
The fixing of shield and guards should only be replaced with fixings of the same or an equivalent type.
Inspection
Inspection
Inspection acceptance
acceptance
acceptance criteria:
criteria:
criteria:
-
It is not possible to reach the shaft or fan
-
The shield and guard must be securely mounted
-
Ensure that the screws are tightened
Procedure
Procedure
Procedure in
in
in case
case
case of
of
of non
non
non---acceptance:
acceptance:
acceptance:
-
Fix and/or replace the shield or guard.
Shaft
Shaft
Shaft seal
seal
seal
Rubber
Rubber
Rubber seals
seals
seals
Motor bearings
Preventive maintenance
Replace
Replace
Replace after
after
after 12
12
12 months:
months:
months:
(one-shift) Complete shaft
seal
Replace when replacing the
shaft seal
Maintenance after leakage
(leakage normally starts
slowly)
Replace
Replace
Replace at
at
at the
the
the end
end
end of
of
of the
the
the day:
day:
day:
Complete shaft seal
Replace when replacing the
shaft seal
Planned maintenance
-
Regular inspection for
leakage and smooth
operation
-
Keep a record of the pump
-
Use the statistics for
inspection planning
Replace
Replace
Replace after
after
after leakage:
leakage:
leakage:
Complete shaft seal
Replace when replacing the
shaft seal
Yearly inspection is
recommended
-
Replace complete bearing
if worn
-
Ensure that the bearing is
axially locked (See motor
instructions)
Lubrication
(Use food approved greas or
oil)
Before
Before
Before fitting
fitting
fitting
Lubricate the O-rings with
silicone grease or silicone oil
Before
Before
Before fitting
fitting
fitting
Silicone grease or silicone oil
See section 6.2 Relubrication
intervals
Pre
Pre
Pre---use
use
use check
check
check
CAUTION!
CAUTION!
CAUTION!
Fit the electrical connections correctly if they have been removed from the motor during servicing.
(See pre-use check in section 3 Installation).
Pay
Pay
Pay special
special
special attention
attention
attention to
to
to warnings!
warnings!
warnings!
1. Start and stop the motor momentarily
2. Ensure that the pump operates smoothly.
27
Содержание LKH Series
Страница 1: ...ESE00698 EN30 2022 07 Original manual Instruction Manual LKH Centrifugal Pump...
Страница 2: ......
Страница 64: ...7 Parts list and service kits The drawing shows the LKH pump sanitary version 64...
Страница 69: ...69...
Страница 70: ...LKH Shaft seal and service kits If inducer 57 is retrofitted Pump inlet may have to be slightly ground 70...
Страница 72: ...LKH Shaft seal and service kits If inducer 57 is retrofitted Pump inlet may have to be slightly ground 72...
Страница 75: ...75...