![Alfa Laval LKH Evap ESE01861-EN4 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/alfa-laval/lkh-evap-ese01861-en4/lkh-evap-ese01861-en4_instruction-manual_2895172038.webp)
6 Technical data
It is important to observe the technical data during installation, operation and manintenance.
Inform the personnel about the technical data.
6.5
Noise emission
Pump Type
Sound pressure level (dBA)
LKH-5
60
LKH-10
69
LKH-15
72
LKH-20
70
LKH-25
74
LKH-35
71
LKH-40
75
LKH-45
70
LKH-50
75
LKH-60
77
LKH-70
88
LKH-75
79
LKH-85
86
LKH-90
75
LKH-112
70
LKH-113
69
LKH-114
68
LKH-122
75
LKH-123
77
LKH-124
80
SolidC-1
68
SolidC-2
72
SolidC-3
73
SolidC-4
72
MR-166
76
MR-185
82
MR-200
81
MR-300
82
GM
54
FM-OS
61
The above LKH noise levels are the same for LKHPF, LKHI, LKH UltraPure, LKH Evap, LKHex.
The above SolidC noise levels are the same for SolidC UltraPure.
The noise measurements have been carried out with original motor and shroud, approximately at the Best Efficiency Point (BEP)
with water at ambient temperature and at 50 Hz.
Very often the noise level generated by the flow through the process system (eg. valves, pipes, tanks etc.) is much higher than
what is generated by the pump itself. Therefore it is important to consider the noise level from the total system and take the
necessary percussions with regards to personal safety if required.
38
www.sks-online.com
www.sks-webshop.com
Содержание LKH Evap ESE01861-EN4
Страница 2: ...www sks online com www sks webshop com...
Страница 32: ...32 www sks online com www sks webshop com...
Страница 47: ...47 www sks online com www sks webshop com...