CONTACT CSI FOR MORE INFORMATION | CSIDESIGNS.COM | [email protected] | 417.831.1411
3 Installation
Read the instructions carefully and pay special attention to the warnings!
NC = Normally closed.
NO = Normally open.
A/A = Air/air activated.
3.4 Fitting actuator/bracket/handle on the valve (optional extras)
S
Stteepp 11
B
Brraacckkeett//iinnddiiccaattiioonn::
1. Fit the bracket as shown.
2. Fit and tighten the screws.
3. Fit the activating ring/indication pin as shown.
Screw for bracket
Bracket
TD 403-121
Drain hole
Direction
of rotation
Activating ring/
indication pin
S
Stteepp 22
A
Accttuuaattoorr//bbrraacckkeett -- N
NC
C::
1. Ensure that the valve is closed by checking the position of the
groove of the disc stem top.
2. Fit the actuator/bracket in accordance with chapter 5.3
Assembly of valve - LKB/LKB-2/LKB-LP, Step 4.
NC actuator
N
Noo pprreessssuurree!!
TD 403-122
C
Clloosseedd
S
Stteepp 33
A
Accttuuaattoorr//bbrraacckkeett -- N
NO
O::
1. Ensure that the valve is open by checking the position of the
groove of the disc stem top.
2. Fit the actuator/bracket in accordance with chapter 5.3
Assembly of valve - LKB/LKB-2/LKB-LP, Step 4.
NO actuator
N
Noo pprreessssuurree!!
TD 403-123
O
Oppeenn
S
Stteepp 44
A
Accttuuaattoorr//bbrraacckkeett -- A
A//A
A::
1. Ensure that the valve is open by checking the position of the
groove of the disc stem top.
2. Supply compressed air to the actuator.
3. Fit the actuator/bracket in accordance with chapter 5.3
Assembly of valve - LKB/LKB-2/LKB-LP, Step 4.
A/A actuator
A
Aiirr pprreessssuurree!!
O
Oppeenn
TD 403-124
12