![Alfa Laval IsoMix External Drive Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/alfa-laval/isomix-external-drive/isomix-external-drive_instruction-manual_2895066022.webp)
5 Operation
Study the instructions carefully and pay special attention to warnings! Always check the machine before operation. Alfa Laval
recommends a soft starter for the machine to reduce the load on tank and machine. For operation instructions from motor
supplier see chapter 9.3 Drive unit instructions.
5.4
Troubleshooting
Problem
Cause/result
Remedy
Not starting
-
Defect
-
Dismantle gear motor, check for correct rotation
-
Replace gear motor
-
Fault at power supply
-
Check power supply connection
-
Check voltage and frequency correspond with motor
nameplate
-
Check frequency converter adjustment correspond with
motor nameplate
Gear motor
-
Mixer section stuck
-
Withdraw the IMXD from the tank and check if the mixer
section is completely stuck – for remedy see below
-
Obstructed
-
Check that mixer head can rotate freely without striking
anything
-
Turn hub and check unrestricted rotation. Remove stem
and hub. Remove foreign materials/material build-up
on stem, hub and inside nut. Clean ball races and ball
retainer w. balls. Reassemble machine
Mixer section
-
Mechanical defects
-
Hold body so stem part is downward and rotate to check
that bevel gears work together. Inspect teeth on stem
and hub for deformation
-
If hard particles get stuck between stem nut and stem or
hub and hub nut, the particles may damage the parts
Vibrations
Shaft
-
Damaged
-
Contact Alfa Laval
Unusual sounds
-
Find root cause of sound
-
Change and/or repair parts
Leakage
Gear motor
-
Oil leakage
-
Repair or replace gear motor
Performance
-
Deviation from normal operation
-
Operation must be according to specification
-
Upstream errors
-
Check if supply valve is fully open
-
Check if inlet pressure to machine is correct
No or insufficient liq-
uid flow
-
Clogging
-
Check supply line for restrictions
-
Remove nozzles and check for clogging
Motor stops/12
red flashes on
frequency converter
-
Clogging
-
Jamming of rotating parts
-
Turn off power supply to frequency converter until red
light stops flashing. Turn on power again
-
Remove IMXD from tank.
-
Dismantle spray section and remove objects that jam the
rotating parts.
22
Содержание IsoMix External Drive
Страница 1: ...100000727 EN1 2018 11 Original manual Instruction Manual Alfa Laval IsoMix External Drive IMXD...
Страница 2: ......
Страница 43: ...9 Appendix 9 1 Declaration of Compliance 43...
Страница 44: ...9 Appendix 9 2 Drive unit lubrication 44...
Страница 45: ...9 Appendix 45...
Страница 46: ...9 Appendix 46...
Страница 47: ...9 Appendix 47...
Страница 48: ...9 Appendix 48...