17/33
ALFA IN a.s. ©
www.alfain.eu
V5
Encoder 2 + confirmation button
V6
LED - lights up when the material thickness is displayed on the left
display.
V7
LED - lights up when the wire feed speed is displayed on the left
display.
V8
Button: Select synergy display
V9
LED - lights up when the left display shows the current - the expected
value the welder wants.
V10
The display shows:
1. Welding current size
2. The size of the welding current in the electrode
3. Feed rate
4. Material thickness
5. Secondary parameter name
V11
The display shows:
1. Welding voltage size
2. Correction
3. The value of the choke
V12
LED - shine when voltage data is displayed on the right display
V13
Button: Correction selection
V14
LED - lights up when wire feed speed correction is set
V15
LED - shines when the right display shows data about the choke
V16
Encoder 1
V17
LED - shines when 2T mode is selected
V18
LED - shines when 4T mode is selected
V19
LED - shine when stair mode is selected
V20
Button: 2T/4T/stairs
SELECTION OF THE WELDING METHOD
1. Long press encoder
V5
to enter the method selection menu.
2. Rotate encoder
V5
to select
ELE
(coated electrode MMA),
MAN
(MIG/MAG manual),
SYN
(MIG/MAG synergic). Confirm the selected
method by pressing encoder
V5
.
3. For the
SYN
method, use the
V16
encoder to set the synergy program
number.
SYN METHOD
The synergy curves are welded in the PB position (fillet weld, horizontal, inclined
from above). For welding in other positions, parameter correction is necessary.
AXE 250-320 PULSE SMART (AL)
ø 0.8
ø 1.0
ø 1.2
SG/Fe
With 82% CO
2
18%
0 *
1 *
2 *
SG/Fe
With 92% CO
2
8%
3 *
4 *
5 *