9.2
Display Tank Levels
This menu item shows the current tank levels and amount dispensed.
Step 1:
From main menu, select (3) System Setup, (2) Tanks and scroll
to (1) Display Tank Levels.
Step 2:
Pressing the L and R arrow keys will scroll through the current tank
levels and the amount dispensed.
Step 3:
Pressing F2 will print a Tank Level Summary ticket.
9.3
Entering Tank Refill Information
Enter tank refill information as follows:
A. Log in to system using PIN code.
NOTE:
Only Managers may access this function.
B. Go to (3) System Setup in main menu.
C. Scroll to (2) Tanks
D. Scroll to (2) Tank Refill Input
E. Enter the tank number you wish to refill
F. Enter the new quantity in the tank.
G. Press F2 to save.
H. Repeat for any additional tanks.