5.5
Waste Tank Level Alerts
This menu displays item displays the level of the waste tank. The system will
warn you when the waste tank is full. The level is calculated based on the
amount of fluid dispensed by all of the meters. By default the use of the waste
tank is turned off. If use of the waste tank is desired, proceed as follows:
Step 1:
From main menu, choose (3) System Setup, (2) Tanks and scroll
to (5) Set Tank Level Alerts.
Step 2:
Enter Tank Number 7 (waste tank) and proceed as follows:
A. Enter the MAX capacity of the waste tank in the units previously
selected).
B. Press F1 to change units associated with waste tank.
NOTE:
Entering a MAX capacity of 0 will deactivate the waste
tank feature.
C. Enter the Warning Level (% of tank maximum).
D. Enter the Stop Level (% of tank maximum).
E. Press F2 to save.