WARNING
Ensure the hose does not contact any high
temperature surfaces, or it may melt and leak
causing a fire. After the cylinder is placed inside
the heater, secure the cylinder with block belt
tightly.
WARNING
A leak test must be performed annually and
each time a cylinder is hooked up or if a part
of the gas system is replaced,
and whenever
any gas components are being replaced
or serviced.
WARNING
Never use an open flame to check for gas leaks.
Be certain no sparks or open flames are in the
area while you check for leaks. Sparks or open
flames will result in a fire or explosion, damage
to property, serious bodily injury, or death.
Regulator / Cylinder
connection
Leak Check Diagram
10. Leak testing: See leak testing diagram for areas to check. Turn all
burner controls to the off position. Turn gas supply valve on.
Brush a half-and-half solution of liquid soap and water onto all joints and
connections of the regulator, hose, manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the
part replaced with one recommended by the Customer Care department
and have the patio heater inspected by a certified gas installer.
WARNING
If the leak cannot be stopped,
immediately shut off the gas
supply, disconnect it, and have
the patio heater inspected by a
certified gas installer or dealer.
Do not use the patio heater until
the leak has been corrected.
WARNING
Do not smoke while performing
this test, and remove all sources
of ignition.
9
9. Connect the gas hose and regulator after that
connect the regulator to the gas cylinder.