NTSA3/9 171130

Refer to diagram 1, hanging the heater on the wall. Drill four 9/64”

holes to fasten the heater to the wall. Install two 1/4”X1/2” hex head

lag screws (supplied with the heater ) into the upper two holes.

Tighten these screws until their heads are about 1/8” from the wall

surface. The screws must be threaded through the wall into a

framing member or backing board to support the heater weight.

Hang the heater on the two upper screws. Locate the two 1/4”X1”

hex head lag screws(supplied with the heater) then install them into

the two lower mounting holes. Tighten to lock the heater in place.

See Diagram 1 for the heater location details and the necessary

clearances to combustible materials.

Never operate the heater without rocks in place! Otherwise it may

cause fire, only use the original sauna rocks or the rocks for use in

heater. Use of any other type of rock may void the heaters warranty.

Rinse the rocks with water before placing through the heater.

Carefully place the rocks loosely so that the air can circulate through

the heater. Packing the rocks too tightly may cause the heater high

limit switch to trip. The rocks must fully cover the heating elements.

Attach the guard with the screws provided.

Electrical installation must be made by a licensed electrician in

accordance with the National Electrical Code and local regulations.

All the wiring connection inside the heater has been done in

factory and carefully checked.

For on-heater control unit, customer only need to connect the power

supply, temperature sensor cable. Remove the compartment cover

from the front of the wiring box, route the feed wires through the

right holes provided in the bottom of the heater, connect the power

wires to the terminal TB1, route the temperature sensor cable

through the left holes provided in the bottom of the heater, connect

the cable to the terminal TB2,

For heater with wall-mount digital control unit, customer need to

connect the power supply to the terminal block in control box.

Connect the 6*12AWG+GND rubber cable wire and 2-p wire of

manual reset thermostat KT2, between control box and heater.

Connect the 6*12AWG+GND rubber cable wire to the terminal TB1,

connect the 2-p wire to the terminal TB2.

SECTION 2: MOUNTING OF SAUNA HEATER

WARNING

The use of accessory

attachments not

recommended by the

appliance manufacturer

may cause injuries

Fire sprinkler systems

used inside any sauna

room should be

properly rated for sauna

room temperatures.

Do not pour chlorinated

pool or spa water on

heater. Excessive water

use on heater may

cause damage and void

warranty

Electric Shock

Hazard-High voltage

exists within this

equipment. There are no

user serviceable parts

in this equipment. All

installation and service

to this equipment

should be performed by

qualified licensed

personnel in

accordance with local

and national codes.

Do not construct

sauna room so as to

restrict air flow through

the bottom of the heater.

Packing the rocks too

tightly may cause the

heater high limit switch

to trip

SECTION 3: PLACING OF ROCKS (See Diagram 13)

SECTION 4: ELECTRICAL HOOK-UP

INSTALLATION AND OPERATING INSTRUCTIONS

Page 4

Содержание NTSA Series

Страница 1: ...at failure to recognize the need to exit the room unawareness of impending hazard fetal damage in pregnant women physical inability to exit the room and unconsciousness WARING The use of alcohol drugs...

Страница 2: ...family use only NTSA and NTSC series sauna heaters are designed for small sauna rooms NTSA 30 90 173 4 W 15 D 243 4 H NTSC 30 90 173 4 W 113 4 D 243 4 H MOUNTING BRACKET LOCATION AND MINIMUM DISTANCE...

Страница 3: ...not necessary if customer do not install the bulb nor the fan 1 Chassis 2 Heating element 3 Heating elements installation plate 4 Base plate locking screw 5 Transformer On heater control unit only 6...

Страница 4: ...unit customer only need to connect the power supply temperature sensor cable Remove the compartment cover from the front of the wiring box route the feed wires through the right holes provided in the...

Страница 5: ...nd put back the cover Sensor wire must be routed completely separate as per low voltage electrical wiring codes from any wiring carrying over 50 volts Only sauna heater with wall mounted digital contr...

Страница 6: ...NTSA3 9 171130 DIAGRAM 5 DIAGRAM 4 INSTALLATION AND OPERATING INSTRUCTIONS Page 6...

Страница 7: ...T TEMP SENSOR BOX MAIN BOARD TRANSFORMER SUB BOARD HEATING ELEMENTS MANUAL RESET THERMOSTAT CONTROLLER NTS 100C or NTS 100F P1 P2 J2 P4 P5 TEST J8 J9 J10 J5 J6 J1 P3 J12 J3 220 240VAC POWER INPUT F2 F...

Страница 8: ...EATING ELEMENTS SAUNA ROOM SUB BOARD MAIN BOARD TEMP SENSOR BOX TRANSFORMER CA3 9A K7 K1 K9 K8 J2 KT2 K2 K5 K6 K4 K3 J1 U U1 U2 V2 V1 V CONTROL BOX SAUNA ROOM CONTROLLER 4 3 2 1 L F1 F2 POWER INPUT 22...

Страница 9: ...panel is equipped with water proof connector and 16 5 feet control wire Please connect one end of the control wire to the water proof connector of the panel and another end to the connector on the con...

Страница 10: ...mode If button pressed in preset mode or preset time is over heater enters heating mode If button pressed in heating mode or heating time is over heater stop to heating SECTION 9 NTS 300 CONTROL OPERA...

Страница 11: ...ing down Press this button again to restore to original status LIGHT CONTROL This button is used as ON OFF switch for ordinary sauna light 40W120VAC FAN CONTROL Press this button to turn on off fan fo...

Страница 12: ...tic heating control function compares room temperature with user set value and then automatically decides groups of element to turn on When working time is over heater stop to heating 3 Button and fun...

Страница 13: ...ttons when the appropriate unit appears on the display Then temperature will be displayed in the chosen form Ex factory value is and Illumination model setting Hold and at the same time for over 3 sec...

Страница 14: ...to normal range and please restart the heater as well If the thermostat or heater cannot be restarted please check temperature limiting thermostat KT1 or heating elements relays please refer to Diagr...

Страница 15: ...ller rocks in first around the outer perimeter of the heating chamber 2 Completely fill all four sections front 2 center sections between elements and back 3 In the outer sections use smaller rocks pl...

Страница 16: ...e the risk of fire caution plate must be mounted on the interior wall above the heater The heater should not be operated without its container properly filled with rocks and the rock guard in place If...

Страница 17: ...Test the heater after maintenance Frequent inspection is required to prevent hazard caused by damaged wire or parts due to moisture Proper ventilation is important check possibility of over heating a...

Страница 18: ...digital control unit please refer to Diagram 7 Open the control box to label all wires in sequence and then disconnect them from mainboard After replacing the damaged mainboard please reconnect all wi...

Страница 19: ...sage disappears automatically once temperature sensor is working properly If the system cannot restore automatically after several minutes please turn off sauna heater and cut off power supply then ch...

Отзывы: