15
Indoor humidity:
display range:
20% to 90% (‘LO’ at <20%: ‘Hi’ at >90%) (at temperatures between 0°C and 60°C)
functional range:
20% to 90% relative humidity
resolution: 1%
accuracy:
+/-5% at 25°C (77°F)
memory display:
history of the past 24 hours, MIN/MAX humidity with time and date
alarm:
HI/LO alarm
Outdoor humidity:
display range:
1% to 99% (‘LO’ at <1%: ‘Hi’ at >99%)
functional range:
1% to 99% relative humidity
resolution: 1%
accuracy:
+/-3% at 25°C (77°F)
memory display:
history of the past 24 hours, MIN/MAX humidity with time and date
alarm:
HI/LO alarm
Air pressure:
measuring units:
hPa, inHg, mmHg
display range:
540 to 1100hPa
resolution:
1hPa, 0.01inHg, 0.1mmHg
accuracy:
+/- 5hPa, +/- 0.15inHg, +/- 3.8 mmHg (970~1030 hPa) at 25°C (77°F)
forecasts:
sunny, partially cloudy, cloudy, rain, storm, snow
memory display:
history of the past 24 hours, MIN/MAX air pressure with time and date
alarm:
HI/LO alarm
Wind speed:
measuring units:
mph, m/s, km/h, knots
display range:
0~112mph, 50m/s, 180km/h, 97knots
resolution:
0.5mph or 0.5knot or 0.5m/s
accuracy:
< 5m/s: +/- 0.5m/s
> 5m/s: +/- 6%
display units:
average, wind gust
memory display:
history of the past 24 hours, MAX wind gust with direction, time and date
alarm:
HI alarm (for average and for wind gust)
Wind direction:
number of wind directions: 16
Rainfall:
measuring units:
mm, inch
display range:
0-9999mm (0~393.7inch)
resolution:
0.4 mm (0.0157 in)
accuracy:
+/- 7%
display units:
actual rainfall, this day, this week, this month
memory display:
history of the past 24 hours
alarm:
HI alarm
DCF radio controlled clock:
synchronisation
automatic or off
display
HH:MM:SS/day and date
time format
12hr AM/PM or 24hr