22
BATTERY REPLACEMENT
Outdoor unit:
After replacing the batteries in the outdoor
unit(s), the outdoor unit must again be regis-
tered on the indoor unit.
To do this, follow the instructions in the sec-
tion ‘To register additional outdoor units’.
SYSTEEM FAILURE
In case of a possible system failure, the
indoor and/or outdoor unit must be reset.
Press the
RESET
(6) button of the outdoor
unit. The indication LED on the front panel
will illuminate for 1 second to inform you.
The outdoor unit is now reset.
Use a paperclip to press the reset button of
the indoor unit. This button is located behind
the reset hole at the rear.
RESET
(18). The
display will switch off and the indoor unit is
restarted. All connection procedures must
now be repeated.
If this doesn’t solve the problem, please
contact the Alecto service department: www.
alecto.nl
ENVIRONMENT
At the end of its lifespan, this product should
not be discarded as normal domestic waste,
but is must be taken to a collection point for
the recycling of electric and electronic equip-
ment.
Don’t throw away exhausted batteries,
take them to your local depot for small
chemical waste.
SPECIFICATIONS
Indoor unit:
measuring range:
0°C to 50°C (32°F to122°F)
resolution: 0.1°C
measuring range air humidity:
20% to 95% rel. air humidity
resolution: 1%
power supply:
mains voltage, 230Volt
output 4,5 VDC, 200mA,
connection of outdoor units:
max. 3
clock:
DCF-77 Time signal, Quartz backup
Outdoor unit:
measuring range:
-20.0ºC to 70ºC (-4ºF to 157.9ºF)
resolution: 0.1°C
measuring range air humidity:
25% ~ 95% rel. air humidity
resolution: 1%
power supply:
2x 1,5V battery, format AAA, alkaline
transmit frequency / range:
433MHz / up to 30 meter.
data transmissie every 5 min.