Troubleshooting
Trouble
Possible cause
Suggested remedy
Engine will not start
1. Low on fuel or oil content
1a Fully fill tank. Ensure fuel is fresh
1b Ensure oil is at the the correct level.
Refer page 18-19 of this manual.
1c Ensure the generator is horizontal and
not on an angle.
1d Turn the fuel tap lever to the right
in a clockwise direction to turn OFF
the fuel tap / lever(23). Loosen the
carburettor drain screw. Allow the fuel
in the carburettor bowl to totally drain.
When the fuel has stopped draining,
turn the fuel tap / lever to the left in an
anti-clockwise direction to turn ON and
fuel starts running out of the carburettor
drain. If so, tighten the screw on the
drain and allow the carburettor to fill
with petrol.
1e If the fuel from the tank does not pass
through the carburettor drain above,
you need to drain the fuel tank (27),
remove the fuel tap / lever (23) and
inspect the fuel extension filter (22).
2. Engine On/Off switch (2) in “Off”
position
2. Press the engine On/Off switch (2) to
the “ON” position as indicated by an “I”.
3. Faulty spark plug (20)
3. Replace or clean spark plug (20) Refer
page 27.
4. Choke lever (16) in wrong position
4. Adjust choke lever (16) accordingly
Refer to page 22.
5. Fuel shut-off valve in closed position
5. Open fuel shut-off valve
6. Unit loaded during start-up
6. Remove load from unit
7. Spark plug (20) wire loose
7. Attach wire to spark plug (20)
8. Old fuel in carburettor
8. Fuel will deteriorate in the carburettor
fuel bowl very quickly. Open the drain
screw in the bowl of the carburettor until
fresh fuel runs through.
9. If all of the above checked ok
9. Take unit to service centre