Trouble
Possible cause
Suggested remedy
No electrical output
1. Faulty receptacle
1. Have service centre replace receptacle
2. Overload has been triggered
(red Overload light on).
2. Remove all appliances. Stop the
generator, and restart. Reconnect
appliances but with reduced load.
3. Faulty power cord
3. Have an electrician replace cord.
4. 240Va.c Outlet Power On/Off switches (1)
turned off.
4. Check the 240Va.c Outlet Power On/Off
switches (1) are “ON”.
Repeated overload
1. Overload
1. Reduce load
2. Faulty cords or equipment
2. Check for damaged, bare, or frayed wires
on equipment. Replace.
Generator overheating
1. Generator overloaded
1. Reduce load
2. Insufficient ventilation
2. Move to adequate supply of fresh air
3. Octane rating of fuel too high
3. Drain fuel and use fresh unleaded fuel
Generator keeps stopping, or
is operating rough
1. Check oil level
1. Add oil so oil is at the correct level. Refer
page 18-19 of this manual.
2. Generator not sitting on flat
and level surface
2. Move generator to a level and
flat surface
3. Motor needs to be cleaned of carbon
3. Remove, check and clean spark arrestor if
needed. Remove, clean or replace spark
plug (20).
For other issues not covered in this chart, please call Customer Service on
1300 889 028.