Replace the water intake screw (7) at the bottom
now before proceeding.
NOTE: Ensure the water intake pipe is submerged in
the water which needs to be transferred.
3. Fill the pump housing with water. This
accelerates the priming process (Fig Z).
4. Priming is complete when air is expelled from
the system & / or the unit is filled with water to
the level reaching the bottom of the intake pipe
(Fig AA shows external view, and birds eye view
of water level required).
5. Re-assemble by inserting back the coarse filter
(2) and non return valve (3) (Fig AB) ensuring it is
secure in position, then secure the water filler
cap (1) using the spanner (8) (Fig U).
Priming your Garden Pump
Once the preparation of
the pump is complete,
you are ready to prime
the pump.
1. Connect the pump
to the mains power
supply in conjunction
with an RCD (Residual
Current Device) as
suggested, and turn
on the mains power (Fig AC).
2. Press the “MODE” button once, and your pump will begin to operate
(Fig AD).
3. Depending on the suction height (distance between pump and the
water), and the amount of air remaining in the intake line, priming has
begun and will take between 10 seconds to 1 minute.
4. If the pump fails to prime, it will need to be re-filled with water, as per
the detail in the previous section.
5. The pump is primed and ready to operate correctly when the water
flows continuously without any air splutter.
6. To stop the pump, either turn off the pump at the mains power, or press
the “MODE” button 4 times (Fig AE) which will put the pump into power
on mode.
You are now ready to select your pumps operational mode.
NOTE: If the pump is to be un-installed after the initial installation,
it must always be re-primed when it is re-installed and used again.
Z.
AB.
AE.
X4
X1
AA.
AC.
AD.
LOOSEN
TIGHTEN
Y.
X.
COARSE
FILTER
NON
RETURN
VALVE
V.