NOVA 120 Pointing model user manual
5
The image quality is weak and shows a vertical trailing in DEC direction. This is quite normal with badly polar aligned
mounts.
If the pointing model has been previously created, and injected into the mount software, the speed model will be
calculated and applied.
Despite the poor polar alignment, the 600s unguided exposure is perfect, because the mount software could
compensate for this error automatically based on the pointing model. Since the mount can never be perfectly polar
aligned, the speed model is a real asset for your mount.
Even, more the next picture shows a raw single 900s unguided exposure that would be impossible to achieve without
the speed model and refraction speeds compensations.