NOVA 120 Pointing model user manual
29
Then enable all mount errors, and click “
Compute
” The fit error is displayed right bottom and shows that 1.2 arcmin
error is achieved by fitting to all fields. The previous RMS error with no pointing model is 5.0 arcmin.
There is some improvement, but better can be obtained.
Do some try and test by checking and unchecking mount errors (checkboxes), and the press “
Compute
” to evaluate the
result.
19.6 arcsec RMS error is been now achieved, using this set of enables / disables. This is a very good performance,
because the RMS pointing error has been reduced from 5 arcmin (600 arcsec) down to 19.6 arcsec which is a ratio of
30.6
fold!