VR5 Product Manual. Rev. 1.0
10
Fig 5. Range selection
Select fullrange or HP at 80Hz or 100 Hz
Fig 6. Low-pass filtering
Optional setting for low-pass filtering at 80 Hz or 100 Hz
Optional settings:
5. Installation
Now the VR5 is dedicated to this channel; Next you can make a choice of filter settings within the preset: 80Hz high-pass, 100Hz high-pass or full-range operation.
The Alcons VHIR™ processing ensures a flat phase response down to 200Hz with minimal latency; This enables the user to select any Alcons subwoofer to
seamlessly work with the VR5, with optimized phase response.
Optional settings in combination with a subwoofer (BF121 in example): The VR5 preset can be set on high-pass filtering at 100Hz, depending on the requirement
(typically, the 100Hz setting is preferred in higher SPL applications).
To match the VR5 and obtain a flat system response, the BF121 preset needs to be set on the same frequency preset, 80Hz or 100Hz.
(See fig 5)
In applications where the VR5 is positioned further away from the subwoofer, the VR5 preset may be set on full-range, with the accompanying sub set on 80Hz.
(See fig 6)