ALCO AL-85851 Скачать руководство пользователя страница 1

ALCO Sales & Service Co.

 

Tel

 

800.

323.4282

www.

alcosales

.com  

info

@

alcosales

.com

© Copyright, 2011, all rights reserved 

Page 1  

AL-85851

 EXIT MOTION SENSOR 

INSTALLATION AND OPERATING INSTRUCTIONS 

1. DESCRIPTION
The 

AL-85851

 is a passive infrared motion detector specifically designed to release a magnetic 

lock from the inside for free egress.  Unlike burglar alarm type detectors, the 

AL-85851

 

special features 

are 

appropriate to this use.  The lock control function is fail safe so that 

the magnetic lock will safely release if power is cut to the detector.  A relay is also present 
to  send  a  REX  (request  to  exit)  signal  to  an  access  control  system  (if  one  is  present)  and 
therefore shunt an alarm report.  A time extension feature avoids the problem of the unit 
resetting  if  a  person  momentarily  stops  moving  just  before  exit.    Tight  control  of  the  exit 
detection  pattern  allows  maximum  security  from  the  outside  and  avoidance  of  inadvertent 
activation from the inside. 

Since egress from a magnetically locked door can be a safety issue, make sure you are 
complying with local building codes.  Contact your building and/or fire prevention 
department. 

2. PHYSICAL INSTALLATION
2.1  PLACEMENT OF THE UNIT
The 

AL-85851

 is intended for indoor use only.  It is positioned with respect to the inside of the 

door so that its detection pattern will “see” a person approaching the door while maintaining 
good  security  from  the  outside.    There  are  different  options  as  to  where  the  unit  is  placed 
depending on variables in the application. 

FIG. 1:  PLACEMENT OPTIONS FOR THE SENSOR 

FOR TRAFFIC CONTROL
APPLICATIONS, MOUNT THE
SENSOR IN THE CENTER OF
THE DOOR WITH THE
PATTERN AS SHOWN

FOR SECURITY
APPLICATIONS, THE
PATTERN SHOULD SWEEP
ACROSS THE EXIT DEVICE
BUT MISS THE BOTTOM OF
THE DOOR.  THE SENSOR IS
POSITIONED BEYOND THE
HINGE SIDE OF THE DOOR

WHEN A DOORKNOB IS
PRESENT IN A SECURITY
APPLICATION, THE
PATTERN CAN BE MADE
MORE NARROW

THE SENSOR CAN BE
POSITIONED AT THE
SIDE FOR SECURITY
APPLICATIONS ON
DOORS AT THE END
OF CORRIDORS

The simplest method of placing the unit is for traffic control applications.  A traffic control 

application is one where you do not expect any attempt at breaking in from the outside.  The 

[email protected]   

|

    800.323.4282  

|

   www.alcosales.com

Содержание AL-85851

Страница 1: ...e make sure you are complying with local building codes Contact your building and or fire prevention department 2 PHYSICAL INSTALLATION 2 1 PLACEMENT OF THE UNIT The AL 85851 is intended for indoor us...

Страница 2: ...cover The appearance of the interior is shown in Figure 2 Note that the interior electronics is mounted on a rotating barrel which is locked by the Barrel Locking Screw shown in Figure 2 Loosen this...

Страница 3: ...TO ALARM PANEL DOOR SWITCH TO ALARM PANEL ALARM SIGNAL WHICH IS CLOSED WHEN DOOR IS CLOSED OPENS TO ALARM ALARM SIGNAL WHICH IS OPEN WHEN DOOR IS CLOSED CLOSES TO ALARM IN DEVICE C1 NC1 NO1 IN DEVICE...

Страница 4: ...NO1 3 5 ACCESS CONTROLLED EGRESS DOOR In some jurisdictions the combination of a magnetic lock access control system and exit detector such as the AL 85851 can be considered an access controlled egres...

Страница 5: ...ou need to understand how the unit s control outputs operate in a detection event In the rest condition green LED on no detection the lock control transistor is conducting and the REX relay is deenerg...

Страница 6: ...control relay can be altered by changing jumper settings see Section 5 but the REX relay always operates 50 milliseconds before and one second after the lock control transistor Figure 8 shows the tim...

Страница 7: ...entry security Before doing this set the time set jumper to the 1 2 second position shown in the drawing to the right As you are adjusting the pattern you will make many quick tests of the unit and t...

Страница 8: ...iming screw settings you must also finalize the degree of barrel assembly rotation You don t want the unit seeing the surface of the door itself as this can lead to false detection so in the common ca...

Отзывы: