128 mm
291 mm
12 mm
1
2
3
4
5
6
7
8
C
0
9
BUS
BUS
BUS
1
2
3
4
5
6
7
8
C
0
9
3
1
2
3
DESCRIPTION
System whereby the entrance panel incorporates a numeric keypad (1) which enables the user to call the telephone in a flat by keying in a code
previously assigned to the telephone (Programming the telephone). It also incorporates a numeric display (2) which shows the visitor the code
which has been keyed in.
Acting in parallel with this panel, it is possible to install another panel, or several panels, with a directory (3) whose purpose is to inform the
visitor of the code he should compose on the keypad to call the desired flat.
Characteristics:
System which makes it possible to carry out medium and large scale installations. It is possible to install up to 4 telephones per apartment.
The system makes it possible to manage:
-
Buildings with up to 999 telephones (150 telephones per riser. For a greater number of telephones, carry out the installation in several stages.
See the appropriate diagram)
- Housing estates of up to 99 buildings with keypad entrance panel. Up to 999 telephones per building.
- Housing estates of up to 99 buildings with pushbutton entrance panel. Up to 96 telephones per building.
2-wire BUS-type connection, both between entrance panels and to telephones in flats.
The communication BUS to telephones is without polarity of connection.
If a short circuit occurs in the BUS, the text F0 flashes in the entrance panel display until the short circuit disappears
The programming of each telephone is carried out from the main entrance panel of the installation. The entrance panel confirms that the
telephone has successfully received the code by emitting a confirmation tone.
It is possible to activate the electric lock directly from the entrance panel by composing a previously-defined 5-digit code (Door-opening
function). Four different 5 digit codes are permitted. Possesses a security system which disables this option when a certain number of consecutive
attempts have been made to enter an incorrect code. Both the number of unsuccessful attempts permitted and the length of time during which
the function remains disabled are values which can be configured.
It is likewise possible to configure the call tone, the number of times the call tone is repeated, the time setting to answer the call, the maximum
time setting for conversation, the number of digits in the code of each telephone and the time during which the electric door lock is activated.
Note:
The configuration of the above-mentioned parameters is carried out from the entrance panel itself (Entrance Panel Configuration).
To configure the entrance panel, a configuration menu is available. This menu is accessed from the keypad of the entrance panel itself.
1
2
3
4
5
6
7
8
9
0
C
PORTERO DIGITAL -
DIGITAL
DOOR ENTRY SYSTEMS
- PORTIER NUMÉRIQUE
GRF-211
KPD-001
PAK-41000
9800033 PAK-41000 ENTRANCE PANEL WITH DIGITAL AUDIO UNIT, NUMERIC DISPLAY AND KEYPAD WITH WHICH
TO MAKE CALLS TO FLATS
I
ndividual exterior entrance panel for digital door entry system installations. Houses the GRF-211 audio unit and the
KPD-001 numeric keypad.
9610034 GRF-211
DIGITAL AUDIO UNIT WITH NUMERIC DISPLAY
Digital audio unit for entrance panel with numeric keypad. With a built-in numeric display which allows the code composed
on the panels keypad to be seen. Has volume controls both for the entrance panel and for telephones. Generation of
electronic call with audio confirmation for the visitor.
The electronic circuit is protected against short circuits.
9650002 KPD-001
NUMERIC KEYPAD
Element which enables the visitor to enter the code of the flat which he wishes to call or the code which activates the
electric lock directly. Audio confirmation when a key is pressed, with the possibility of regulating the volume of the beep.
Incorporates the electric lock relay as well as two double contact relays, relays 1 and 2, useful for applications in which it
is necessary to direct additional elements (See "How to connect KPD-001", page 18). It is possible to activate relay 1 by
means of the auxiliary pushbutton on the telephone in the flat (See the data sheet of the telephone). Likewise it is possible
to activate relay 2 by pressing any key on the keypad. In both cases, the time that the relay remains active can be set,
since this is a configurable value.