ALBIN PUMP ALHP Series Скачать руководство пользователя страница 13

8. 

TECHNICAL SPECIFICATIONS

8.1  

General information of the pulsation dampener

Description 

Value

Max. operating pressure 

16 bar (232 psi)

Ambient temperature 

-20°C to 45°C (-4°F to 113°F)

Product temperature 

-10°C to 70°C (14°F to 158°F)

Storage temperature

-40°C to 70°C (-40°F to 158°F)

PED directive

97/23/EC

Max. volume

See type plate

8.2  

Torque values and weight

Description

ALHP20 ALHP40 ALHP50 ALHP100

ALHP125

Hose clamp (Pos 6)

S-band 
12mm

SL72

SL94

Supra 140-
148

Supra 162-
174

Thread 

---

M10

M12

M10

M10

Torque value [lb-ft]

4,13

33,19

58,26

33,19

33,19

Key width [mm]

7

17

19

17

17

Flange bracket / body (Pos 13)
Thread 

---

M10

M16

M16

M16

Torque value [lb-ft]

---

33,19

146,03 146,03

146,03

Key width [mm]

---

17

24

24

24

Seal flange / body (Pos 16)

(Pos 13)

Thread 

M6

M10

M12

M12

M12

Torque value [lb-ft]

7

33,19

58,26

58,26

58,26

Key width [mm]

CHC 6

17

19

19

19

Pulsation dampener [Kg]

3,5

35

90

135

220

Hose [Kg]

0,2

1,9

3,3

12,4

14,6

Содержание ALHP Series

Страница 1: ...since 1928 ALBIN PUMP ALHP in line pulsation dampener Manual of maintenance...

Страница 2: ...5 4 DESCRIPTION 5 4 1 Identification of the product 5 4 2 Operation of the pulsation dampener 5 4 3 Pulsation dampener hose 6 4 4 Pulsation dampener selection 6 5 INSTALLATION AND COMMISIONING 7 5 1...

Страница 3: ...iendly processing of packaging materials contaminated lubricant and oil Always observe the local rules and regulations with respect to processing non reus able parts of the pulsation dampener 1 4 Spec...

Страница 4: ...2 3 Compliance Pressure Equipment Directive The pulsation dampeners as mentioned on the front cover are in full compliance with the Euro pean Pressure Equipment Directive 97 23 EC 2 4 Use In Potentia...

Страница 5: ...be accompanied by a fully completed and signed safety form as present in the back of this manual The safety form must be applied to the outside of the ship ping carton Parts which have been contaminat...

Страница 6: ...ressure relief valve 4 3 Pulsation dampener hose The pulsation dampener hose liner material should be chemically resistant to the product to be pumped Dependent on the specific requirements of your ap...

Страница 7: ...he hose pump Minimise the distance between pump and pulsation dampener The pulsation dampener may be installed in either the horizontal or vertical position The pulsation dampener must be suitably sup...

Страница 8: ...ball valve pos 17 gently Filling medium will now enter and pressurize the vessel Check the pressure gauge pos 20 for the actual pressure inside the vessel 5 Pressurize the vessel to approximately 85...

Страница 9: ...ampener hose CAUTION After maintenance has been carried out and before switching the pump back on ensure that all valves present in the pipe work are opened 6 1 Cleaning the pulsation dampener hose in...

Страница 10: ...de of the new hose matches the colour code of the old used hose 1 Check all parts to be mounted for any damage and replace when necessary 2 Grease all metal parts which are not corrosion protected and...

Страница 11: ...ener hose Pressure loss at pulsation dampener housing Damaged O ring pos 4 or 5 Replace the O ring con cerned Pressing ring pos 7 incor rectly mounted Tighten to the specified torque settings see Torq...

Страница 12: ...7 DIMENSIONS...

Страница 13: ...weight Description ALHP20 ALHP40 ALHP50 ALHP100 ALHP125 Hose clamp Pos 6 S band 12mm SL72 SL94 Supra 140 148 Supra 162 174 Thread M10 M12 M10 M10 Torque value lb ft 4 13 33 19 58 26 33 19 33 19 Key wi...

Страница 14: ...s certifications and local representatives please visit www albinpump com ALBIN PUMP reserves the right to incorporate our latest design and material changes without notice or obligation Design featur...

Отзывы: