6. Operation
AUTOMATIC PAY-OUT (default): slip into the acceptor slot the note to be exchanged in coins or
tokens: the machine will pay-out through hopper n.1 (1.00 $); if hopper n.1 is/gets empty, pay-out
takes place through hopper n. 2.
MANUAL PAY-OUT (max. changeable value per pay-out = 100 $): slip into the acceptor slot the
note to be exchanged in coins or tokens: the display will show the corresponding credit, as well as
the available coin values; use the buttons by the display side to choose the desired coins: the
relevant hopper will pay out your change.
NOTICE: the User will be able to choose his change coins only if the machine has been preset for
MANUAL MODE. When placing your order for the HAMMER 2, it is recommended that you
express such preference, as well as your preferred Key Mode: the machine shall then be delivered
already preset for Manual Mode, and the signs on the buttons will be consistent with your wished
Key Mode: ‘OK’ and ‘
↑↓
’ in case of Scroll Mode, or the preset values in case of Straight Mode.
It remains anyway possible to set up later the Pay-out Mode and the Keys Mode (SCROLL MODE
or STRAIGHT MODE) as you wish - see 7.2.4
PERIPHERAL UNITS SET UP
.
If there are not enough coins in the hopper to fulfil the whole exchange request, the remaining credit
shall be displayed and retained in memory.
If an interruption occurs because of power breakdown or switch-off, the remaining credit shall be
displayed at switch-on and paid out.
7. System configuration
7.1 Default menu
The HAMMER 2 is preset by default as follows:
Board Parametres
Pay-out mode
= AUTOMATIC
Bonus
= DISABLED
Level sensors
= DISABLED
HopperOne [ccTalk] Parametres
Hopper number
= 1
Coin value
= Coins / $ 2.00 (*)
Hopper number
= 2
Coins value
= Coins / $ 2.00 (*)
(*) since the machine can accept to change 100 $, the max. q.ty of payable pieces has been fixed to
250, to avoid fast depletion.
BillyOne or OryOne [ccTalk] note acceptor Parameters
$ 5.00 - …. - $ 100.00 = ENABLED
AL66 S [ccTalk] coin selector Parameters
$ 0.05 - $ 0.10 - $ 0.20 = DISABLED
$ 1.00 - $ 2.00 = ENABLED
If any variation is made, it will be possible to restore the default configuration as follows:
enter the initial menu, scroll by UP and DOWN keys and choose
RESTORE DEFAULT CONFIGURATION
then press OK; the message
DEFAULT CONFIG
.
RESTORED
will be displayed.
NOTICE: the
RESTORE DEFAULT CONFIGURATION
command resets the default PIN code (0000)