AL55/66 Technical manual Version 1.1
6.5.2.9 Command 232 [hexE8], Perform self-test
Coin selector respond to command with one or two bytes of data according to
table 6.3. First byte is fault code and second is optional data, usually representing fault
sensor number(
from 1 to 3
).
Code
Fault
Optional data
Comment
0
OK No fault detected
-
-
2
Fault on inductive sensor
Sensor number
-
3
Fault on credit sensor
-
Control opto sensor 2
6
Fault on diameter sensor
-
-
18
Fault on reject sensor
-
Control opto sensor 3
33
Power supply out of limits
-
-
34
Temperature out of limit
-
Optional
255
Unspecified fault code
-
-
Table 6.3 Fault codes for AL55/66 coin selectors
Inductive sensor numbers are:
01
Upper inductive sensor
02
First lower inductive sensor
03
Second lower inductive sensor
Message format is:
Host sends:
[Dir] [00] [01] [E8] [Chk]
Coin s. respond:
[01] [01/02] [Dir] [Fault c.][Data opt.] [Chk]
Example of message string for coin selector(
address 2
) with no fault detected is:
Host sends:
[02] [00] [01] [E8] [15]
Coin s. respond:
[01] [01] [02] [00] [00] [FC]
No fault detected
Example of message string for coin selector(
address 2
) with first lower sensor fault
detected is:
Host sends:
[02] [00] [01] [E8] [15]
Coin s. respond:
[01] [02] [02] [00] [02][02] [F7]
Fault on first lower sensor detected
6.5.2.10 Command 231 [hexE7], Modify inhibit status
With this command host is able to inhibit the acceptance of some or all coins.
Acceptance or inhibition is set with a two byte mask sent by host.
Bits from 0 do 15 determinate coin positions from 1 to 16
36
.
Number of coin channels in new ALBERICI coin selectors AL55/66 is same as number of
position(
16
). Message format is:
Host sends:
[Dir] [02] [01] [E7] [LSB Mask.] [MSB Mask.] [Chk]
Coin s. respond:
[01] [00] [Dir] [00] [Chk]
ACK
36
Positions are sent by coin selector during reading credit buffer or error codes (
header 229
)
40