![Alberici AL66 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/alberici/al66/al66_technical-manual_2889491004.webp)
AL55/66 Technical manual Version 1.1
1. General description
Electronic coin selector AL66 is member of third generation of ALBERICI coin selectors.
It is mechanically and electrically compatible with older generation of ALBERICI coin
selectors AL05 and 06. The compatibility with others 3 ½” coin selectors using 10 pole
IDC connectors is maintained as well. It is also possible to change power input polarity
to match with coin selectors AZKOYEN or MONEY CONTROLS mod 3.
Users can simply change coin selector function to fit in to various applications, using our
free programming software. Change is made simply by selection one of the standard
functions described in this document or by creating his own function (“custom”) through
serial interface and terminal window.
There is also possibility for customers to order a special or personal function created by
factory experts. Coin selectors can be delivered programmed or be reprogrammed by
customer with simple copy function.
The new coin selectors have advanced measuring system with three pairs of magnetic
sensors and additional optical measurement of coin diameter.
The “heart” of coin selector is “Freescale”
1
8 bit micro controller of new generation with
36 kB of FLASH memory and high immunity to electro magnetic disturbances
(“automotive”).
The number of coin movement control sensors is increased to
2
.
Power saving mode is supported and has advanced wake up possibility.
In some special version (for telephone cabinet) it is possible to switch off power supply
by applying control signal to one of external 10 pole connector pin.
Power consumption is further reduced in stand by and in power saving mode.
Power supply voltage is more flexible with respect to older generation and EMI
3
resistance is improved.
Firmware up-grade is supported and time for complete up-grade is reduced to approx.
10 seconds.
New generation of coin selectors support safe transfer of data and safe authentication
with RSA (
asymmetric algorithm with private and public key
) crypt algorithms.
1
Ex Motorola
2
Number of control sensors pair could be 1, 2 or 3 in most advanced and secure version
3
Electro Magnetic Interferences
4