17
Instructions for operating the blower only when the door is closed
1.
Press and hold the
Reset/Menu
button
for 3-5 seconds.
2.
The display will read
LIMIT SETUP
. Press the
UP ARROW
button until
the display reads
MODULE CONFIGURATION
. Press the
ENTER
button. The display will read
MOD A…
3.
Press the
UP ARROW
button until the display reads
MOD H DEFROST
.
Press the
ENTER
button 2 times.
4.
Press the
UP ARROW
button until the display reads
O3….
in the upper right
hand corner. Press the
ENTER
button.
5.
The cursor will be flashing underneath the first letter of the first word in the upper
left hand corner. Press the
UP ARROW
button until the display reads
DOOR NOT CLOSED.
6.
Press the
ENTER
button, the cursor will be flashing under
NO
. Press the
UP ARROW
button to change this to
NC
.
7.
Press the
ENTER
button, the cursor should not be flashing.
8.
Press the
RESET
button until the display reads
DOOR READY.