Albalá Ingenieros | Manual
ASW3000C01
The following functions of the ASW3000C01 can be performed remotely:
- Selection of the operating mode.
- Configuration of the error conditions.
- Status supervision for the input signals.
4.5.1. Details of the ASW3000C01 registers
The ASW3000C01 module provides control and status registers that can be read and
written by means of specific commands described in the communication control
module user manuals.
The parameter information grouped in the CONTROL or RAM sections is stored in
volatile memory. Any modifications to the parameters will be lost when the module
power supply is disconnected unless the "EEPROM Save" button within the software
has been pressed.
The EEPROM section parameters are rarely used and are stored directly in non-volatile
memory.
The STATUS section parameters are read-only and cannot be modified.
The parameters that can be controlled and supervised remotely for each version of
the firmware are listed below:
VERSION 1.X
CONTROL
Name
add
ext
msk
snmp trap
Description
MODE
0x00
0x03
Y
Y
Allows selecting the switching mode
0=Full auto, 1=Half auto, 2=Manual
BUZZER
0x00
0x04
Y
N
Allows buzzer operation
0=Disabled, 1=Enabled
INPUT
0x01
0x01
Y
Y
Selected input
0=Main, 1=Reserve
GPI_MASK
0x02
0x01
Y
N
Allows masking fail of GPIs
0=Disabled, 1=Enabled
PRESENCE_MASK
0x02
0x02
Y
N
Allows masking fail of signal presence
0=Disabled, 1=Enabled
SYNC_L_MASK
0x02
0x04
Y
N
Allows masking fail of sync loss
0=Disabled, 1=Enabled
SYNC_B_MASK
0x02
0x08
Y
N
Allows masking fail of sync byte error
0=Disabled, 1=Enabled
PAT_ERR_MASK
0x02
0x10
Y
N
Allows masking fail of PAT error
0=Disabled, 1=Enabled
PAT_CC_MASK
0x02
0x20
Y
N
Allows masking fail of PAT continuity counter
0=Disabled, 1=Enabled
BITRATE_MASK
0x02
0x40
Y
N
Allows masking fail of out of range bitrate
0=Disabled, 1=Enabled
NULL_PCK_MASK
0x02
0x80
Y
N
Allows masking fail of null packet ratio
0=Disabled, 1=Enabled
INVERT_GPI1_POL
0x03
0x01
N
N
Changes GPI1 polarity to normally closed
0=No, 1=Yes
INVERT_GPI2_POL
0x03
0x02
N
N
Changes GPI2 polarity to normally closed
0=No, 1=Yes
25
Содержание ASW3000C01
Страница 2: ...ASW3000C01 ...
Страница 8: ...Albalá Ingenieros Manual ASW3000C01 1 3 Block diagram 8 ...
Страница 10: ...Albalá Ingenieros Manual ASW3000C01 ASW3000C01 10 ...
Страница 28: ...Albalá Ingenieros Manual ASW3000C01 ASW3000C01 28 ...
Страница 30: ...Albalá Ingenieros Manual ASW3000C01 ASW3000C01 30 ...
Страница 32: ...Albalá Ingenieros Manual ASW3000C01 ASW3000C01 32 ...
Страница 34: ...Albalá Ingenieros S A Medea 4 28037 Madrid Spain 34 913274453 www albalaing com info albalaing com ...