The lines indicated as GPIO n the silkscreening are assigned as follows:
GPIO5: Error input for the reserve channel.
GPIO4: Error input for the main channel.
GPIO3: Alarm output for the reserve channel.
GPIO2: Alarm output for the main channel.
GPIO1: Indicates selection of:
0V main channel.
+5V reserve channel.
GND: Ground for the module.
During normal operating conditions the alarm outputs GPIO2 and GPIO3 are set to
logic low (transistor on) in order to signal an alarm condition and a no-alarm
condition via a logic high (open collector). This signaling polarity can be inverted using
the control software.