background image

Series AFS8202M

Alba Fiber Systems Inc. Specifications are subject to change without notice.

Page 19 6/20/14

www.albafiber.net

[email protected]

Industrial Redundant Managed Ethernet Media Converter with 2 Ports

1 x 10/100/1000BaseT(X) Port, 1 x 1000M SFP Port

6.0 Web-Based Management

Input the IP address that appears on the label of AFS8202M into browser and the login screen
will pop up as Fig. 18.

Fig. 18 Login Screen

Default User Name:

admin

Default Password:

(no password)

Then click “OK”, you will enter the first page of the system.

Содержание AFS8202M Series

Страница 1: ...th 2 Ports 1 x 10 100 1000BaseT X Port 1 x 1000M SFP Port Installation Operation Instructions Fiber Optic 10 100 1000Mbps Ethernet Transmission System Part Number AFS 8202M 10 100 1000Mbps Industrial...

Страница 2: ...ction 11 5 2 4 SFP Slots 12 5 2 5 Console Port 13 5 3 Front Panel LED Indicators 14 5 4 Product Signal Format Specifications 16 5 5 PoE Specifications 17 5 6 Dimension Figure 17 6 0 Web Based Manageme...

Страница 3: ...7 SNMP System Configuration 54 6 8 Port Status 55 6 9 MAC Table List 56 6 10 IEEE 802 1Q VLANS 59 6 11 PROTOCOL VLANS 60 6 11 1 ASSIGNING PORTS TO VLANS 60 6 11 2 CONFIGURING VLAN ATTRIBUTES FOR PORT...

Страница 4: ...it is operated serviced or repaired Failure to comply with any precaution warning or instruction noted in the manual is in violation of the standards of manufacture warranty and intended use of the un...

Страница 5: ...sories b Propyl Alcohol and lint free tissue or cloth may be used to clean fiber connector tips c Do not use rubbing alcohol mixed with water This can cause additional spots d Clean the fiber by pulli...

Страница 6: ...00Base Auto sensing and compatibility with major Network Protocols The optical interfaces operate at a 1000Mbps Ethernet rate Redundant ring plug and play performance ensures ease of installation no u...

Страница 7: ...Protocols IGMP V1 V2 V3 GMRP GVRP SNMP V1 V2C V3 DHCP TFTP SNTP SMTP RMON HTTP HTTPS TELNET SSH SYSLOG Supports RSTP STP 802 1w d s IEEE802 1D Enhanced mechanisms through QoS TOS DiffServ Supports VLA...

Страница 8: ...SFP Port 5 0 Hardware 5 1 Hardware Installation 5 1 1 Din Rail Installation AFS8202M series are din rail mountable structure This series of equipment s back panel have fixed well in DIN rail way conne...

Страница 9: ...dant Managed Ethernet Media Converter with 2 Ports 1 x 10 100 1000BaseT X Port 1 x 1000M SFP Port Fig 2 Wall Mount Installation Specifications of Screw below Fig 3 meet the standard of the AFS8202M se...

Страница 10: ...P Port Fig 4 Top panel Power Input Terminal Redundancy dual power input by the terminal block as below The standard power specs is DC12V 55V 12V DC 3A 24V DC 1 5A for non PoE switch only PoE switch sh...

Страница 11: ...er net Industrial Redundant Managed Ethernet Media Converter with 2 Ports 1 x 10 100 1000BaseT X Port 1 x 1000M SFP Port 5 2 2 Front Panel Front Panel Fig 5 Is Shown as Below Fig 5 Front Panel 5 2 3 R...

Страница 12: ...Ports 1 x 10 100 1000BaseT X Port 1 x 1000M SFP Port 5 2 4 SFP Slots Insert 1000M SFP modules into each port the SFP can be either 1 fiber or 2 fibers A SFP of LC Double fiber details seen Fig 7 belo...

Страница 13: ...Single fiber Connection Method details seen Fig 10 below Fig 10 SC Single fiber Connection Method C Copper SFP details seen following Fig 11 Fig 11 Copper SFP 5 2 5 Console Port Network management por...

Страница 14: ...ia Converter with 2 Ports 1 x 10 100 1000BaseT X Port 1 x 1000M SFP Port Fig 12 RJ45 Console Ports Pinout Fig 13 RJ45 8 Pin to DB9 F Cable Wiring 5 3 Front Panel LED Indicators All the media converter...

Страница 15: ...Panel AFS8202M LED STATUS INDICATORS LED indicator lamp Status Explanation PWR 1 Green On Power 1 Up Red On When power supply is no more than 10V SYS On Switch works properly PWR 2 Green On Power 2 U...

Страница 16: ...duct Signal Format Specifications The tables below identify the specifications for the various signals that these fiber units transmit receive CONNECTORS Optical SFP Dependent Power Terminal Block Ele...

Страница 17: ...1000BaseT X Port 1 x 1000M SFP Port 5 5 PoE Specifications Max Output Power 15 4W in 802 3af 30W in 802 3at Output Voltage 46 to 57 VDC depends on external power supply Max Output Current 350 mA in 8...

Страница 18: ...cations are subject to change without notice Page 18 6 20 14 www albafiber net sales albafiber net Industrial Redundant Managed Ethernet Media Converter with 2 Ports 1 x 10 100 1000BaseT X Port 1 x 10...

Страница 19: ...Managed Ethernet Media Converter with 2 Ports 1 x 10 100 1000BaseT X Port 1 x 1000M SFP Port 6 0 Web Based Management Input the IP address that appears on the label of AFS8202M into browser and the l...

Страница 20: ...subject to change without notice Page 20 6 20 14 www albafiber net sales albafiber net Industrial Redundant Managed Ethernet Media Converter with 2 Ports 1 x 10 100 1000BaseT X Port 1 x 1000M SFP Port...

Страница 21: ...stem Contact Administrator responsible for the system Maximum length 255 characters System Name Name assigned to the switch system Maximum length 255 characters System Location Specifies the system lo...

Страница 22: ...o control the switch CPU port traffic which used for management The IP address for the switch is obtained via DHCP by default for VLAN 1 To manually configure an address you need to change the switch...

Страница 23: ...VLAN to which the management station is attached Valid IP addresses consist of four numbers 0 to 255 separated by periods IP Mask This mask identifies the host address bits used for routing to specifi...

Страница 24: ...o configure an IP address 1 Click System IP Status Edit 2 Specify the IPv4 settings and enable DNS proxy service if required 3 Click Save Fig 21 shows IP Configuration Fig 21 IP Configuration 6 1 3 SN...

Страница 25: ...are displayed Mode Enables or disables SNTP client requests Server Sets the IPv4 address for up to five time servers The switch attempts to update the time from the first server if this fails it attem...

Страница 26: ...m is no password Password can be set and changed as following Fig 23 Fig 23 System Password Setting Interface 6 2 PoE Use the Power over Ethernet Configuration page to set the maximum PoE power provid...

Страница 27: ...r budget of 80W The switch s power management enables individual port power to be controlled within the switch s power budget Port power can be automatically turned on and off for connected devices an...

Страница 28: ...highest port number is shut down Reserved Power Ports are shut down when total reserved powered exceeds the amount of power that the power supply can deliver In this mode the port power is not turned...

Страница 29: ...al Redundant Managed Ethernet Media Converter with 2 Ports 1 x 10 100 1000BaseT X Port 1 x 1000M SFP Port Fig 24 Configuring PoE 6 2 2 Displaying PoE Status Use the Power Over Ethernet Status to displ...

Страница 30: ...x power 4 0 W Class 2 Max power 7 0 W Class 3 Max power 15 4 W Class 4 Max power 30 0 W Power Requested Amount of power the PD wants to be reserved Power Allocated Amount of power the switch has alloc...

Страница 31: ...Interval 4 Transmission Delay Tx Hold Configures the time to live TTL value sent in LLDP advertisements as shown in the formula below Range 2 10 Default 3 the time to live tells the receiving LLDP age...

Страница 32: ...vertised messages Port Descr The port description is taken from the ifDescr object in RFC 2863 which includes information about the manufacturer the product name and the version of the interface hardw...

Страница 33: ...LLDP Port Statistics Edit 2 Modify any of the timing parameters as required 3 Set the required mode for transmitting or receiving LLDP messages 4 Enable or disable decoding CDP frames 5 Specify the i...

Страница 34: ...m Remote Port ID A string that contains the specific identifier for the port from which this LLDPDU was transmitted System Name A string that indicates the system s assigned name Port Description A st...

Страница 35: ...ws management access clicking on an entry in this field will re direct the web browser to the neighbor s management interface WEB INTERFACE To display information about LLDP neighbors click Monitor LL...

Страница 36: ...1000BASE SX LX LH 1000full NOTE The 1000BASE T standard does not support forced mode Auto negotiation should always be used to establish a connection over any 1000BASE T port or trunk If not used the...

Страница 37: ...Fig 28 Configuration Set or show the port speed and duplex mode Syntax Configuration port_list up down Port_list is used to specified the ports that apply for this command e g to show the ports 1 4 5...

Страница 38: ...albafiber net sales albafiber net Industrial Redundant Managed Ethernet Media Converter with 2 Ports 1 x 10 100 1000BaseT X Port 1 x 1000M SFP Port Fig 29 WEB INTERFACE To configure port connection se...

Страница 39: ...m in switch For each port if Loopback Detection is enabled and Tx Mode is enable the port is actively generating loop protection PDU s If loopback is found the action could be shutdown port or log it...

Страница 40: ...l keep a port disabled until next device restart Port Configuration Port The switch port number of the port Enable Controls whether loop protection is enabled on this switch port Action while the cong...

Страница 41: ...ANDS Configuration Show loop protection of the switch Mode Set or show the loop protection mode of the switch Transmit Set or show the loop protection transmit interval Shutdown Set or show loop prote...

Страница 42: ...he ports before removing a static trunk via the configuration interface When incoming data frames are forwarded through the switch to a trunk the switch must determine to which port link in the trunk...

Страница 43: ...switch trunk links where traffic through the switch is destined for many different hosts Do not use this mode for switch to router trunk links where the destination MAC address is the same for all tr...

Страница 44: ...as following Fig 33 Fig 33 Aggregation Mode Configuration CLI COMMANDS Configuration Show link aggregation configuration Add Add group of port to an aggregation configuration Delete Delete link aggreg...

Страница 45: ...ends of an LACP trunk must be configured for full duplex either by forced mode or auto negotiation Trunks dynamically established through LACP will be shown on the LACP System Status page by path Moni...

Страница 46: ...ion of LACP negotiation on a port to automatically send LACP negotiation packets once each second Use Passive initiation mode on a port to make it wait until it receives an LACP protocol packet from a...

Страница 47: ...nning Tree Protocol IEEE 802 1D i e the switch will use RSTP set to STP forced compatibility mode RSTP Rapid Spanning Tree IEEE 802 1w Bridge Priority Controls the bridge priority Lower numeric values...

Страница 48: ...decrements the hop counts by one before passing on the BPDU When the hop count reaches zero the message is dropped Advanced Settings Edge Port BPDU Filtering BPDU filtering allows you to avoid transm...

Страница 49: ...TP bridge configuration seen as following Fig 35 Fig 35 STP Bridge Configuration CLI COMMANDS Configuration STP bridge level configuration information such as RSTP max age and so on For the detail ple...

Страница 50: ...T Normal Port Configuration PARAMETERS These parameters are displayed Port Port identifier This field is not applicable to static trunks or dynamic trunks created through LACP Also note that only one...

Страница 51: ...000 500 000 Fast Ethernet Half Duplex Full Duplex Trunk 200 000 100 000 50 000 Gigabit Ethernet Full Duplex Trunk 10 000 5 000 Priority Defines the priority used for this port in the Spanning Tree Al...

Страница 52: ...enabled this causes the port not to propagate received topology change notifications and topology changes to other ports TCN messages can cause temporary loss of connectivity after changes in a spann...

Страница 53: ...n is selected the switch derives the link type from the duplex mode A full duplex interface is considered a point to point link while a half duplex interface is assumed to be on a shared link Forced T...

Страница 54: ...or authentication and privacy This community string is associated with SNMPv1 or SNMPv2 clients in the SNMPv3 Communities table page 69 Write Community The community used for read write access to the...

Страница 55: ...t Statistics Overview page to display a summary of basic information on the traffic crossing each port PATH Web Monitor Ports Traffic Overview CLI Port PARAMETERS These parameters are displayed Packet...

Страница 56: ...C Table List Use the MAC Address Table Configuration page to configure dynamic address learning or to assign static addresses to specific ports Switches store the addresses for all known devices This...

Страница 57: ...the switch via the serial interface NOTE If the learning mode for a given port in the MAC Learning Table is grayed out another software module is in control of the mode so that it cannot be changed b...

Страница 58: ...red by Learning command Add Add MAC address Delete Delete MAC address Lookup Maintain or show the Mac address for the specified ports manually Agetime Specified the how long the MAC address entry will...

Страница 59: ...cated anywhere in the network but communicate as though they belong to the same physical segment VLANs help to simplify network management by allowing you to move devices to a new VLAN without having...

Страница 60: ...G PORTS TO VLANS Use the VLAN Membership Configuration page to enable VLANs for this switch by assigning each port to the VLAN group s in which it will participate PATH Configuration VLANs VLAN Member...

Страница 61: ...to S custom port the EtherType also called the Tag Protocol Identifier or TPID of all frames received on the port is changed to the specified value By default the EtherType is set to 0x88a8 IEEE 802...

Страница 62: ...ese frames will be flooded to all other ports Ingress filtering does not affect VLAN independent BPDU frames such as GVRP or STP However they do affect VLAN dependent BPDU frames such as GMRP Frame Ty...

Страница 63: ...be a member of the same VLAN as the Port VLAN ID WEB INTERFACE To configure attributes for VLAN port members 1 Click VLANs VLAN Port Edit 2 Configure in the required settings for each interface 3 Cli...

Страница 64: ...system log entry Message The message text of the system log entry WEB INTERFACE To display the system log 1 Click System Log 2 Specify the message level to display the starting message ID and the num...

Страница 65: ...em log configuration Server Mode Set or show the system log mode to enable or disable Server Address Configure system log server IP address Level Configure system log level Lookup log_id all info warn...

Страница 66: ...represented as attribute values When saving the configuration from the switch the entire configuration including syntax descriptions is included in the file The file may be modified using an editor an...

Страница 67: ...iles for your switch from the Support section of the SMC Edge Core web site PATH Web Maintenance Software Upload CLI Firmware WEB INTERFACE To upgrade firmware 1 Click Maintenance Software Upload 2 Cl...

Страница 68: ...firmware via http Upgrading Upgrading the firmware via http Information show the current firmware information of this switch 6 15 Factory Defaults Use the Factory Defaults page to restore the original...

Страница 69: ...estore factory default configuration and keep IP address if the keep_ip parameter specified System restore default Restore factory default configuration Restore Default keep_ip 6 16 Restart Device Use...

Страница 70: ...without notice Page 70 6 20 14 www albafiber net sales albafiber net Industrial Redundant Managed Ethernet Media Converter with 2 Ports 1 x 10 100 1000BaseT X Port 1 x 1000M SFP Port Fig 47 Restart D...

Страница 71: ...BER Port COPPER PORT DISTANCE AFS8202M D 1SFP Din Rail 1 x 10 100 1000Base T Tx Port 1 x 1000M SFP Slot 1 1 See SFP options for optional distances fiber type and connector type AFS8202M W 1SFP Wall Mo...

Страница 72: ...ed Alba Security engineer Please attach a statement clearly describing the problem Alba will repair defective product under warranty free of charge to our customers Any unauthorized modification of ha...

Отзывы: