ALAT UJI OMEGA DOH-SD1 Скачать руководство пользователя страница 6

5

(If you press buttons too slowly in setup mode, the screen will revert to the normal display. To
return to the setup sequence, press and hold the LOGGER SET button again. To move ahead to
the next field in the sequence or to the next parameter, press the HOLD/ESC button.)

Pressing the REC/ENTER button causes the word “no” or “yES” to appear over the term
“Sd-F”. Press the 

 button to make a selection. Choose “yES” whenever a new SD card

is being used, or when a used card is being repurposed (from use with another SD card
instrument or a camera, for example) and all data on it is to be erased. Choose “no” to
preserve any data on a card previously used with this instrument.

If you choose “yES”, after you press the REC/ENTER button the instrument will prompt
you to confirm that decision by displaying the term “Ent” below “yES” and sounding
three beeps. To confirm that you want to begin the erasure/formatting procedure, press
the REC/ENTER. “Ent” will then flash several times and the instrument will sound
another three beeps to confirm that the SD card has been erased and formatted.

4.

 

Set the date and time.

 Once the SD card has been set up, the word “dAtE” will appear in

the center of the display, along with the flashing value “00.00.00” at the lower left, above
“yy.mm.dd”. Set the current year by pressing the 

 or 

 button repeatedly until the

correct value appears above “yy”. Press the REC/ENTER button to store the setting. The
next screen that appears will have the value above “mm” flashing. Use the 

 or 

 button

to navigate to the current month and press the REC/ENTER button to store the setting.
When the next screen flashes the value above “dd”, again use the 

 or 

 button to

navigate to the current day and press the REC/ENTER button to store the setting.

Once you have set the date, the display will prompt you to set the hour, minute and second of
the current time. Again use the 

 or 

 buttons to navigate to the correct values, and the

REC/ENTER button to store the settings.

5.

 

Set the datalogging sampling time

. Once the date and time have been set and stored, the

display will show a value below the letters “SP-t”. Press the 

 or 

 button to decrease or

increase the flashing hour value until the desired number appears below “SP-t”. Press the
REC/ENTER button to store that setting. The minutes value will then flash. Press the 

or 

 button to decrease or increase the value and then press the REC/ENTER button to

store that setting. Finally, press the 

 or 

 button to decrease or increase the flashing

seconds value and then press the REC/ENTER button to store that setting.

6.

 

Enable or disable auto power off

. Once the sampling time has been set and stored, the

display will show the word “yES’ over the term “PoFF”. Press the 

 button until the

desired automatic power off management scheme (“yES” for enable; “no” for disable) is
displayed. Press the REC/ENTER button to store the selection. If enabled, the power off
function shuts off the DOH-SD1 after a period of inactivity of ten minutes.

7.

 

Enable or disable the beeper.

 Once the auto power off function has been enabled or

disabled, the display will show the word “yES” over the word “bEEP”. Press the 

button until the desired setting (“yES” or “no”) is displayed, and then press the
REC/ENTER button to store the selection.

Содержание OMEGA DOH-SD1

Страница 1: ...DOH SD1 Disolved Oxygen Meter With Data Logging SD Card...

Страница 2: ...atic vs manual datalogging 9 Transferring data from the SD card to a computer 10 Specifications 12 Maintenance troubleshooting tips 13 Replacement parts accessories 14 1 FEATURES Office Jl Radin Inten...

Страница 3: ...microcontroller to display readings from 0 to 20 milligrams liter mg L with a resolution of 0 1 mg L and an accuracy of 0 4 mg L Because it is microprocessor based the DOH SD1 can make full use of th...

Страница 4: ...l the probe Two spare probe heads with diaphragm set A 2 GB SD memory card This user s manual Fig 1 shows all of the controls and indicators on the front back top bottom and side of the DOH SD1 Famili...

Страница 5: ...e Replace the cover by replacing the two screws 2 Install an SD card To prepare for setup also install the supplied 2 GB SD memory card or another card with a capacity from 1 GB to 16 GB in the socket...

Страница 6: ...current month and press the REC ENTER button to store the setting When the next screen flashes the value above dd again use the or button to navigate to the current day and press the REC ENTER button...

Страница 7: ...pper portion of the display matches your altitude in meters Then press the REC ENTER button to store this value as the temporary default 12 Compensate DO measurements for altitude in feet Once DO meas...

Страница 8: ...obe head with electrolyte To calibrate the DOH SD1 use the following procedure while referring to Figures 1 and 3 CALLOUTS FOR FIG 3 3 1 Probe Plug 3 2 Probe Handle 3 3 Temperature sensing Metal 3 4 P...

Страница 9: ...el once Insert the probe at least 4 inches 10 cm into the liquid to be measured Wait a few minutes for the instrument to automatically compensate for any difference in temperature between the probe an...

Страница 10: ...which the instrument was set up press the LOGGER SET button which has the words Sampling check stenciled below it once To change the sampling time perform Step 5 of the setup procedure 1 To start aut...

Страница 11: ...ation press the REC ENTER button to save the setting This causes the value to stop flashing and the P to return 6 To end manual datalogging press the REC ENTER button and hold it for at least three se...

Страница 12: ...11 5 Typical Excel graphics only screen 6 Typical Excel mixed graphics data screen...

Страница 13: ...Automatic Compensation for altitude 0 to 29 200 ft 0 to 8 900 meters Compensation for liquid salt content 0 to 50 Datalogging sampling time range 1 second to 8 hours 59 minutes 59 seconds DO probe typ...

Страница 14: ...t corner of the display it s time to replace the six AA batteries that power it although measurements will remain valid for several hours after the low battery indicator first appears Replacing the ba...

Страница 15: ...ACEMENT PARTS OPTIONAL ACCESSORIES DOE SD1 Spare oxygen probe DOEH SD1 Spare probe head and diaphragm set DOEL SD1 Electrolyte for probe APAPTER ST 9 VDC adapter for 110VAC power supply RS232 SD RS232...

Страница 16: ...15 NOTES...

Страница 17: ...e Jl Radin Inten II No 62 Duren Sawit Jakarta 13440 Indonesia Workshop Jl Pahlawan Revolusi No 22B Jakarta 13430 Indonesia Phone 021 8690 6777 Hunting Fax 021 8690 6777 Mobile 62 816 1740 8925 Fax 021...

Отзывы: