Groups and Scheduled Group 1 Examples 

(cont'd.) 

Functions 90/91

:  

Use Function 90 and 91 (see page 29) to create a window of time where if any Group 1 User Code is entered within the 

programmed window, a 

relay 

will be activated for 2 seconds.  The relay can be configured to disarm a burglary control panel.  See page 29. 

 

1.    Enter Program Mode (if not in already). 
2.    Connect relay to a burglar control panel with switch input for disarming. 
3.    Using Function 2, create User 4 with a User Code of "456789": 

Press 

;

 

2

 

;

 

4

 

;

 

4

 

5

 

6

 

7

 

8

 

9

 

:

4.    Because User 4 does not have a default Group association, make User 4 a member of Group 1 using Function 35: 

Press 

;

 

3

 

5

 

;

 

4

 

;

 

1

 

:

5.    Use Function 90 to set the time to open the window (8:30 A.M. all days of the week) allowing any Group 1 member to close the relay for 2 

seconds.  

Note:  

Only 1 relay closure will occur even if another member of Group 1 enters their User Code.  Use Function 91 to set the 

time to close the window (10 A.M. for all days of the week): 

      

Function 90  

(Open Window Time) = 8:30 A.M.:  Press 

;

 

9

 

0

 

;

 

0

 

;

 

0

 

8

 

3

 

0

 

:

 

      

Function 91  

(Close Window Time) = 10:00 A.M.:  Press 

;

 

9

 

1

 

;

 

0

 

;

 

1

 

0

 

0

 

0

 

:

 

6.    Exit Program Mode (hold down any key for 3 seconds). 

 

The relay will close, one time only, when a member of Group 1 enters their User Code between 8:30AM and 10:00AM.  If a Group 1 User 

does not enter their User Code during the specified window, Functions 90/91 remain inactive 

The alarm panel will have to be armed at night by the User or by an automatic schedule function of the alarm panel. 

 
 

Functions 92/93

:  

Use Function 92 and 93 (see page 30) to create a window of time where if any Group 1 User Code is entered within the 

programmed window, 

Group 4 Users 

will be enabled. 

 

1.    Enter Program Mode (if not in already). 
2.    Using Function 2, create User 4 with a User Code of "456789": 

Press 

;

 

2

 

;

 

4

 

;

 

4

 

5

 

6

 

7

 

8

 

9

 

:

3.    Because User 4 does not have a default Group association, make User 4 a member of Group 1 using Function 35: 

Press 

;

 

3

 

5

 

;

 

4

 

;

 

1

 

:

4.    Using Function 17, disable Group 4.  (Group 4 will need to be "disabled" before it can be "enabled" later). 

Press 

;

 

1

 

7

 

:

5.    Use Function 92 to set the time to open the window (8:30 A.M. all days of the week) allowing any Group 1 member to enable Group 4.  Use 

Function 93 to set the time to close the window (10:00 A.M. all days of the week).   

      

Function 92  

(Open Window Time) = 8:30 A.M.:  Press 

;

 

9

 

2

 

;

 

0

 

;

 

0

 

8

 

3

 

0

 

:

 

      

Function 93  

(Close Window Time) = 10:00 A.M.:  Press 

;

 

9

 

3

 

;

 

0

 

;

 

1

 

0

 

0

 

0

 

:

 

6.    Exit Program Mode (hold down any key for 3 seconds). 

 

The lock will now enable Group 4 User Codes if User 4 (or any Group 1 member) enters their User Code between 8:30 A.M. and 10 A.M.  
If no Group 1 member arrives to enter their User Code between 8:30 A.M. and 10 A.M., Group 4 User Codes will not be enabled and will 
remain disabled all day. 

The device will have to be manually locked each night by entering the following command using Function 82: 

;

 

4

 

6

 

:

 

The device can also be programmed to automatically disable Group 4 members each night at 5 P.M. by using Function 82: 

;

 

8

 

2

 

;

 

0

 

;

 

1

 

7

 

0

 

0

 

:

 

Test the device by creating User 222 (with User Code 466466) and adding User 222 to Group 4: 

;

 

2

 

;

 

2

 

2

 

2

 

;

 

4

 

6

 

6

 

4

 

6

 

6

 

:

 

;

 

3

 

5

 

;

 

2

 

2

 

2

 

;

 

4

 

:

 

Remember to exit Function Mode when programming is complete. 

 
 
 

Содержание Trilogy DK3000 Series

Страница 1: ...f Standalone Access Control Systems AL IR1 PRINTER AL DTM DATA TRANSFER MODULE DL WINDOWS PROGRAMMING SOFTWARE DK3000 345 Bayview Avenue Amityville New York 11701 For Sales and Repairs 1 800 ALA LOCK For Technical Service 1 800 645 9440 Publicly traded on NASDAQ Symbol NSSC ALARM LOCK 2007 ...

Страница 2: ...dows Software Note The DK3000 is not a complete lock system and should be thought of as a lock control ling device The DK3000 s Primary Entry and Auxiliary relays can be used to activate or deacti vate a door strike or a door magnet locking device In a typical application the DK3000 will en ergize its Primary Entry Relay upon the keypad entry of a valid user code The relays used in the DK3000 are ...

Страница 3: ...common schedules see page 28 Real time clock and calendar see page 21 Programmable Timeout Functions see page 20 User Access Methods Keypad Entered User Codes see page 17 User Features 2000 Users see page 17 Six pre defined Administration User Levels including Master Installer Manager Supervisor Print Only and Basic User Codes see page 8 User Code Lengths from 3 6 digits Service Code One Time Only...

Страница 4: ...ansfer the program from the AL DTM to the lock s via a double ended mini banana plug DB9 to DB9 Serial Cable Enroll User Codes into DL Windows then transfer this new User Code data from the computer to the AL PRE via this 9 pin DB9 to DB9 serial cable Once the data is in the AL PRE you can transfer the data to the lock via the double ended mini banana plug see above thus avoiding the need to use a...

Страница 5: ...ed to get your lock to start working To begin programming you must first enter something called Program Mode What is Program Mode Most technical people find working with hardware easy they use tools to make fixes or changes to hardware But with the soft ware inside the lock you enact changes you interface through the keypad The software has only two modes Normal Mode and Program Mode When you want...

Страница 6: ...ty a Programming Level as to their ability to use or make changes to the lock What is a Programming Level The Programming Level defines the range of programming tasks a User is allowed to perform The higher the Level the more pro gramming tasks the User is allowed with Master allowing ALL tasks Note Since the Programming Level is closely associated with the type of User and their abilities a User ...

Страница 7: ...s to a temporary worker Simply enter the User 297 User Code into the lock key pad Later when the temporary worker enters the User 300 User Code into the lock keypad the User 300 User Code allows access for one time only and then becomes disabled Later if you wish to grant the temporary worker re access simply re enter the User 297 User Code and the User 300 User Code will be re enabled again for o...

Страница 8: ...ype For example DK Series locks can hold hundreds of Users in its programming memory and each User is associated with a User Number see definition of User Number in the previous Terminology section and therefore a specific Programming Level as follows Master Always associated with User number 1 Is always en abled and can program all functions Abbreviated as Programming Level M Installer Always ass...

Страница 9: ...Information General Program Mode Information If a wrong key is pressed during code entry hold any key continuously until the error sound is heard 7 short beeps this will clear the entry Re enter the key sequence again All program sequences are followed by the key 2 short beeps indicate a successful program sequence Enabling Disabling Users By User Number 3 Disable User 3 _ _ _ 4 Enable User 4 _ _ ...

Страница 10: ...in DL Windows and transfer the program from your computer to an AL DTM via an AL PCI cable then transfer the program from the AL DTM to the lock s via a double ended mini banana plug The hand held AL DTM is useful because you do not have to transport or find electricity for your computer Data can also flow in reverse from the lock through the AL DTM back to the computer for examination IBM COMPATA...

Страница 11: ...ow the procedure outlined in Quick Start First time Power Up further in this manual When power is re applied to a lock that was already op erational proceed as follows 1 Disconnect battery pack connector 2 With battery power disconnected press and hold down for 10 seconds to insure discharge of all ca pacitors 3 Re connect battery pack lock will sound 3 short beeps If beeps are not heard then rest...

Страница 12: ...put Tamper Output Mounted to Housing Auxiliary Relay Output N O GRAY ORANGE N O BLACK COM WHITE N C N O Push Button Switch N C Alarm System Zone Programmed for 24 Hour Alarm 1 Magnetic Lock 2 Electric Strike 3 Solenoid Device BLACK RED 1 Mag Lock 2 Electric Strike 3 Solenoid 4 Light 5 Siren 6 Video Recorder WHITE WHITE Simplified Power Supply Option Transformer 12 to 24 VAC or DC Recommended Suppl...

Страница 13: ...Source Sounder Device AC DCV Light Source Sounder Device Supply Door Strike Door Strike Power Supply N C POWER SUPPLY OPTIONS Emergency Exit Switch Emergency Exit Switch SUPPLY Simplified Power Supply Option Transformer 12 to 24 VAC or DC Recommended Supply Option Battery Backup 12 to 24V AC or DC WARNING In all cases be sure to allow for emergency exit during a fire or AC power failure Local juri...

Страница 14: ... to be 664433 Press 1 664433 664433 Now that the Master Code has been changed there is no need to change it again unless you want to Since you are still in Program Mode you can now proceed directly below and program various functions Note Programming any Function such as setting the clock follows a consistent 5 step pattern 1 Enter Program Mode 2 Press Function 3 Press and enter data 4 Press to en...

Страница 15: ... that the anticipated sequence does not currently open the lock If the lock does not open the anticipated Master Code can be used as the new Master Code if the lock opens the anticipated Master Code already exists in the lock as a User Code and the anticipated Mater Code should NOT be used Always repeat this procedure with any new anticipated Master Codes Exit Program Mode Hold Down any key for 3 ...

Страница 16: ...ee page 22 Programming Functions Overview Function 48 Enable Passage Mode See page 23 Function 49 Disable Passage Mode See page 23 Function 50 Return Lock to Normal Passage Mode Schedule See page 23 Function 51 Passage Mode Configuration See page 23 Function 52 54 Pass Time See page 23 Function 55 Print Audit Trail See page 24 Function 56 Print User Code List See page 24 Function 57 Print Clock Se...

Страница 17: ...age 5 for more information about Master Codes 3 M USERS Lock Defaults for DK3000 See page 8 Users added will default to a Group Association and a Program Level Ability as follows USER TYPE USER NUMBER GROUP DEFAULT ASSOCIATION MINIMUM PROGRAM LEVEL see page 6 Master 1 M All Programming Abilities Installers 2 3 none 4 Also 3 2 1 Managers 4 6 none 3 Also 2 1 Supervisors 7 9 none 2 Also 1 Print Only ...

Страница 18: ...Program Mode and pressing 5 1157 008 NOTE Up to 4 Timeout Functions may be pending at any one time An error beep will sound when attempting to program more than 4 Timeout Functions 2 Service Code is a One Time Only Code Once it is used it is disabled until enabled again NOTE User Number 297 is used to reset Service Code Use See Terminology Used in this Manual on page 6 for more information and exa...

Страница 19: ...tions Function 12 clears all programmed Schedules and all Timeout Functions To clear All Timeout Functions only see Function 13 below Function 12 will clear all of the following All Schedule Functions 72 through 93 Timeout Functions 5 25 through 34 and Function 47 Note Function 12 also resets Passage Mode and any disabled Groups After using Function 12 your Scheduled Timeout features must be manua...

Страница 20: ...Association As per the chart on page 8 the lock s default programming from the factory associates certain User Numbers with certain Groups To override these default Group associations Function 35 manually associates or disassociates a selected User with a selected Group During programming Groups not selected are then disassociated from the User Function 35 is helpful when the number of Users you w...

Страница 21: ...nd ends at 2AM on the programmed date Enter 4 1 0 0 0 to disable DST All locks leave the factory with DST enabled and pre programmed to the following start and end dates for the USA beginning 2007 Default DST Start Date March Week 2 Sunday Second Sunday in March Default DST End Date November Week 1 Sunday First Sunday in November To program the DST start date using the keypad press 4 1 M M W D whe...

Страница 22: ...example if the clock has already been set to speed up 10 seconds per day and then is found to need an additional 10 seconds then program 20 seconds using Function 43 Example 1 Clock is losing 13 seconds every day enter 4 3 1 3 This example assumes that the Clock Adjust setting was at the factory default of zero Function 57 can be used to print the current Clock Adjust setting Example 2 Clock is ga...

Страница 23: ...Code is entered When the Pass Time expires the lock will re lock automatically Use the functions below to change the Pass Time to 3 10 or 15 seconds The Pass Time is defaulted to 3 seconds Pass Time 4 53 Set Pass Time to 10 Sec 54 Set Pass Time to 15 Sec PASS TIME See Scheduled functions 72 and 73 for Scheduled Passage Mode NOTE Programming Functions cont d 51 Passage Mode Configuration 5 1 _ Mode...

Страница 24: ... Figure 2 above To abort printing press any key for 3 seconds three short beeps will sound Hold the printer over the lock s infrared sensor as shown in Figure 1 and Figure 2 above For use with DL WINDOWS software refer to OI237 AL PCI interface cable is needed 1 3 3 PRINTER DOWNLOADING Hold the printer perpendicular to the Lock s infrared LED as shown in Figure 1 and Figure 2 If the printer has be...

Страница 25: ...r of attempts before lockout must be 1 9 attempts The number of attempts is reduced by half every time the keypad is locked out without a successful code entry default is 6 attempts The attempt count is reset each time a valid code is entered Function 61 determines the length of time the keypad is locked out after a series of unsuccessful attempts default is 15 seconds Used with Function 60 Lockou...

Страница 26: ...med Pass Time The Pass Time is the length of time the lock stays unlocked after a valid User Code is entered See functions 52 54 Use this feature for remote monitoring or other activation as this feature works independently of all other relay options Programming this feature will supersede all other programmed relay features Subsequent relay feature programming will not take effect while this feat...

Страница 27: ...2 8 0 _ _ _ _ _ Day Time 81 Schedule Disable Group 3 8 1 _ _ _ _ _ Day Time 82 Schedule Disable Group 4 8 2 _ _ _ _ _ Day Time 83 Schedule Disable All Groups 8 3 _ _ _ _ _ Day Time 3 Clear All Schedule and Timeout Functions by entering Function 12 To set the time see Function 39 NOTE 72 Schedule Enable Passage Mode Unlock 7 2 _ _ _ _ _ Day Time 73 Schedule Disable Passage Mode Lock 7 3 _ _ _ _ _ D...

Страница 28: ... Monday to Friday 9 for Saturday and Sunday and 0 for all days of week Enter time of day in 24 hour format for example for 2 15 PM enter 14 15 Note Do not use this feature in Residency mode Scheduled Passage Mode Group 1 Activated 89 Passage Mode Close Time Window This Function enabled through keypad only 8 9 _ _ _ _ _ Day Time SCHEDULES GROUP 1 ACTIVATED 3 For your convenience your lock comes pre...

Страница 29: ...Enter time of day in 24 hour format for example for 2 15 PM enter 14 15 Scheduled Relay Activation Group 1 Activated 9 1 _ _ _ _ _ Day Time 91 Relay Activation Close Time Window SCHEDULES GROUP 1 ACTIVATED 3 NOTES 1 Group 1 Disarms a Burglary Control Panel will always disarm an alarm system Arming should be performed by other means such as Alarm Panel Keypad Schedule 2 Use a qualified electrical a...

Страница 30: ...oup 1 User Code is entered within this window Group 4 members will be enabled Group 4 members will still need to enter their User Codes to enter For additional information see Group 1 Activated Features on page 31 For day enter 1 for Sunday 2 for Monday 3 for Tuesday 4 for Wednesday 5 for Thursday 6 for Friday 7 for Saturday 8 for Monday to Friday 9 for Saturday and Sunday and 0 for all days of we...

Страница 31: ...See To Disarm a Burglary Control Panel on page 29 If a Group 1 User does not enter their User Code during the specified window Functions 90 91 remain inactive Function 92 and 93 allow for a window of time to be created where if any Group 1 User Code is entered within the programmed window the User Codes in Group 4 will be enabled If a Group 1 User does not enter their User Code during the specifie...

Страница 32: ...n of the alarm panel Functions 92 93 Use Function 92 and 93 see page 30 to create a window of time where if any Group 1 User Code is entered within the programmed window Group 4 Users will be enabled 1 Enter Program Mode if not in already 2 Using Function 2 create User 4 with a User Code of 456789 Press 2 4 4 5 6 7 8 9 3 Because User 4 does not have a default Group association make User 4 a member...

Страница 33: ...t apply 1 Remote Input switch closed and Function 65 Remote Input enabled 2 Remote Input switch closed and Function 64 Remote Input disabled 3 Failed attempted entry 4 Disabled User or Group 5 Follow Access Granted 6 Group 1 User Code 7 Scheduled Lock Event 8 Scheduled Unlock Event 9 Lock Out 10 Ambush 11 First Key Press 25 Disable Sounder 26 5 sec Delayed Entry 27 15 sec Delayed Entry 28 45 sec D...

Страница 34: ...umber 1 2000 User Code 3 6 digits User Name 1 2 3 4 Group Association For a complete list of user codes obtain a printout from either the remote printer Program Function 56 or using the DL WINDOWS Software Note ...

Страница 35: ...e programmed Up to only 150 using AL DTM2 For Day Enter 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Monday through Friday 9 Saturday and Sunday 0 All days of the week Enter time of day in 24 hour format 00 00 23 59 Time Function Name ...

Страница 36: ... Microsoft Windows 95 98 or NT 4 0 Refers to the User Code for User 298 SERVICE CODE User 300 User Code Allows only one entry then needs to be re enabled by the User 297 User Code to regain access SUPERVISOR CODE User Codes assigned to Users 7 8 and 9 Can only program day to day operation USER CODE Code used by Users Code is 3 to 6 numeric digits long allowing controlled entry VALID CODE An entere...

Страница 37: ...s through the door without USER CODES door is unlocked PRINTER A printout device such as an infrared printer or computer printer PROGRAM MODE A mode allowing program data to be entered through the keypad Only specific Users can program a lock manually by entering their USER CODE followed by the key To exit program mode hold any key until repeated beeps are heard PROGRAMMABLE RELAY FUNCTIONS The re...

Страница 38: ...38 NOTES ...

Страница 39: ...39 NOTES ...

Страница 40: ...on purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall ALARM LOCK be liable for an amount in excess of ALARM LOCK s original selling price of the product for any loss or damage whether direct indirect incidental consequential or otherwise arising out of any failure of the product Seller s warranty as here...

Отзывы: