WIRING
See the Installation Manual for detailed illustrations and
additional information.
External Power:
Red / Black wires - External 12-24 Volts AC or DC
Power Source.
Remote Input:
White / White wires - Wire a Normally Open Contact
to wires (white and white). Momentarily close to allow
device to unlock the door and allow entry.
NOTE:
Remote Input is enabled from the factory.
(See
page 25)
Main/Entry Relay:
The
Main Relay
(also called the
Entry Relay
) is, for
example, used to operate a door strike to allow ac-
cess through a door.
COM-Purple / NO-Gray / NC-Blue - See page 26
(Function 67) for programming options for this relay.
Auxiliary Relay:
The
Auxiliary Relay
is an additional relay used to con-
trol cameras, lights, an audible sounder, etc.
COM-Black / NO-Pink / NC-White - See page 26
(Function 67) for programming options for this relay.
Transient Protection:
Magnetic strikes and magnetic locks can produce
harmful switching transients. To ensure the DK3000
is protected, two transient protection devices are sup-
plied. These protection devices should be wired as
close to the magnetic strike or magnetic lock as pos-
sible (if wiring close to the magnetic strike or lock is
not possible, the protection devices can be wired at
the DK3000 lock).
Note:
Although some magnetic
strikes and magnetic locks do possess transient pro-
tection, our supplied protection devices should always
be used. See wiring diagrams on pages 12-13.
Wiring to Disarm a Burglary Control Panel
Burglary Control Panel wiring. See page 29.
POWER UP
•
When applying power to the lock for the first time
, stop
and follow the procedure outlined in "Quick Start, First time
Power Up" further in this manual.
•
When power is re-applied to a lock that was already op-
erational
, proceed as follows:
1. Disconnect battery pack connector.
2. With battery power disconnected, press
and hold
down
;
for 10 seconds to insure discharge of all ca-
pacitors.
3. Re-connect battery pack (lock will sound 3 short beeps). If
beeps are not heard, then restart at step 1.
4.
Do not press any keys for 15 seconds
.
5. After 15 seconds, the LED will flash red 6 times and 6
beeps will sound.
The lock is now ready for use. The pre-existing program is
loaded from fixed memory. Set the clock using functions 38,
39 and 40.
ERASE ALL PROGRAMMING
(The "out of box" factory default will be loaded)
1. Remove the battery pack.
2. With battery power disconnected, press
and hold
down
;
for 10 seconds to ensure discharge of all ca-
pacitors.
3. Re-install the battery pack (lock will sound 3 short beeps).
If beeps are not heard, then restart at step 1.
4. Within 5 seconds after hearing the 3 short beeps, press
and hold
;
until the lock begins to beep, then release.
5. A series of 5 RED LED and 5 beeps will be heard followed
by 10 seconds of silence, then 3 GREEN LEDs and 3 fast
beeps.
All settings and programming have been erased and the lock
is now ready for use.
Note:
All lock programming can also be
erased (without need to disconnect the batteries) by entering
Function 99.
SPECIFICATIONS
Operating Voltage Range:
10V - 28V AC or DC
For uninterrupted operation, a power source that pro-
vides battery backup is required.
12V Current Consumption
Idle Current: 3ma
Maximum Current: 55ma
24V Current Consumption
Idle Current: 7ma
Maximum Current: 80ma
2 Relays:
SPDT Form C, N/O, N/C, C
8 amps @ 24V AC or DC
24 Volts MAXIMUM