Alarm Controls Corporation 1200LB Скачать руководство пользователя страница 6

INSWINGING DOOR INSTALLATION WITH L- Z BRACKET

STEP 1

FASTEN THE L BRACKET ON THE DOOR FRAME IN A SUITABLE LOCATION.

MOUNT THE MAGNETIC LOCK TO THE L BRACKET. 

MAKE SURE THAT THE MAGNETIC LOCK DOES NOT OBSTRUCT THE

CLOSING OF THE DOOR.

CONNECT THE CORRECT VOLTAGE TO THE MAGNET. 

STEP 2

ASSEMBLE THE  Z BRACKET WITH THE SOCKET HEAD CAP SCREWS

PROVIDED. DO NOT TIGHTEN THE CAP SCREWS AT THIS TIME. THE

Z BRACKET MUST BE ADJUSTABLE.  

STEP 3

MOUNT THE ARMATURE PLATE TO THE ADJUSTABLE SECTION OF THE Z   

BRACKET WITH THE ARMATURE BOLT.  DO NOT REMOVE THE RUBBER

WASHER ATTACHED TO THE ARMATURE BOLT.

USE ONE RUBBER WASHER BETWEEN TWO METAL WASHERS ON THE

ARMATURE BOLT.  THE WASHER ASSEMBLY MUST BE BETWEEN THE 

ARMATURE PLATE AND THE ADJUSTABLE SECTION OF THE Z BRACKET. 

APPLY THE SCREW LOCKING AGENT TO THE ARMATURE BOLT.  

DO NOT OVER TIGHTEN.  ARMATURE MUST ROCK TO ALIGN WITH THE MAGNET.

STEP 4

CLOSE THE DOOR AND ALIGN THE ARMATURE PLATE TO THE MAGNET 

AND APPLY POWER TO THE MAGNET.  LET THE ARMATURE PLATE BOND

TO THE MAGNET. BE SURE THE Z BRACKET ASSEMBLY IS FIRMLY    

AGAINST THE CLOSED DOOR.

TIGHTEN THE CAP SCREWS HOLDING THE Z BRACKET ARMATURE PLATE  

ASSEMBLY. 

FASTEN THE Z BRACKET ASSEMBLY TO THE DOOR WITH THE SCREWS SUPPLIED.

STEP 5

CHECK THE COMPLETED ALIGNMENT AND INSTALLATION OF THE         

MAGNET AND ARMATURE PLATE BY OPENING AND CLOSING THE DOOR    

BY ENERGIZING AND DE-ENERGIZING THE MAGNETIC LOCK SEVERAL

TIMES.
THIS WILL INSURE THAT THE CORRECT OPERATION AND ALIGNMENT

OF THE MAGNETIC LOCK HAS BEEN PROPERLY INSTALLED.    

DOOR

FRAME

L

BRACKET

RUBBER

WASHER

ARMATURE

BOLT

ADJUSTABLE

Z BRACKET

Z BRACKET

ARMATURE

ASSEMBLY

ADJUSTABLE

SECTION OF

Z BRACKET WITH

ARMATURE PLATE

ATTACHED

COMPLETED

INSWINGING DOOR

INSTALLATION

Содержание 1200LB

Страница 1: ...DC BI COLOR LED S P D T 3A RELAY CONTACTS SIGNALS A POWERED SECURELY SEALED DOOR CLEAR ANODIZED U S 28 FINISH STANDARD ALL NON ALUMINUM PARTS ARE PLATED ALARM CONTROLS CORPORATION 19 BRANDYWINE DRIVE...

Страница 2: ...MAGNETIC LOCK BY 5 8 LOWERS MAGNETIC LOCK BY 1 4 MODEL AM 3300 FOR 600 SERIES 1 W x 9 7 8 L MODEL AM 6300 FOR 1200 SERIES 1 1 2 W x 10 1 2 L MODEL AM 3305 FOR 600 SERIES 1 W x 9 7 8 L MODEL AM 6305 F...

Страница 3: ...0 SERIES 3 W x 8 1 4 L x 9 16 H MODEL AM 3325 FOR 600 SERIES MODEL AM 6325 FOR 1200 SERIES COMPRESSION MOUNTS ARMATURE ON FRAMLESS GLASS DOORS ACCOMODATES 60O AND 1200 SERIES FOR 600 AND 1200 SERIES M...

Страница 4: ...AL DOORS ALSO CLASSIFIED IN ACCORDANCE WITH UNIFORM BUILDING CODE STANDARD 7 2 FIRE TEST OF DOOR ASSEMBLIES A COMPLETE LINE OF STANDARD AND CUSTOM REQUEST TO EXIT STATIONS ARE AVAILABLE IMPORTANT FEAT...

Страница 5: ...KET HEADER PLATE 2 FOLD TEMPLATE ON DOTTED LINE TO FORM A 90 DEGREE ANGLE TAPE TEMPLATE AGAINST DOOR HEADER WITH DOOR IN A CLOSED POSITION 1 FROM DOOR FRAME OPPOSITE HINGE SIDE OF DOOR JAMB FOR A PAIR...

Страница 6: ...KET APPLY THE SCREW LOCKING AGENT TO THE ARMATURE BOLT DO NOT OVER TIGHTEN ARMATURE MUST ROCK TO ALIGN WITH THE MAGNET STEP 4 CLOSE THE DOOR AND ALIGN THE ARMATURE PLATE TO THE MAGNET AND APPLY POWER...

Страница 7: ...ANT BE APPLIED TO EACH SURFACE TO PREVENT RUST ALTHOUGH THE MATING SURFACES HAVE BEEN PLATED THIS ONLY NEEDS TO BE DONE WHEN DIRT BUILD UP IS NOTICED THE ARMATURE PLATE BOLT AND THE HEX HEAD SCREWS HO...

Страница 8: ...GA 18 GA 16 GA 14 GA 14 GA 12 GA 10 GA 12 GA 24 GA 24 GA 22 GA 22 GA 24 GA 24 GA 24 GA 24 GA PROBLEM CAUSE SOLUTION LOCK BUZZES INSUFFICIENT HOLDING FORCE DOOR DOES NOT LOCK DOOR STATUS SENSOR NOT WOR...

Страница 9: ...AGNET AND ARMATURE V V N O COM N C WHEN MOUNTING ARMATURE PLATE ON DOOR RUBBER WASHER MUST BE PLACED BETWEEN METAL WASHERS DO NOT EXCESSIVLY TIGHTEN SEX BOLT ARMATURE MUST FLOAT ON DOOR THREAD LOCKING...