Alarm Controls Corporation 1200LB Скачать руководство пользователя страница 4

ALARM CONTROLS CORPOR ATION

“QUALITY SECURITY EQUIPMENT SINCE 1971”

19 BRANDYWINE DRIVE, P.O. BOX 280, DEER PARK, NEW YORK 11729

1 800 645-5538  631 586-4220  FAX 631 586-6500

EMAIL: [email protected]   WWW.ALARMCONTROLS.COM

U.L. LISTED MAGNETIC LOCKS

F

F

O

O

R

R

 

 

A

A

L

L

L

L

 

 

A

A

C

C

C

C

E

E

S

S

S

S

 

 

C

C

O

O

N

N

T

T

R

R

O

O

L

L

 

 

A

A

P

P

P

P

L

L

I

I

C

C

A

A

T

T

I

I

O

O

N

N

S

S

E-Z MOUNT DESIGN

FOR SUPERIOR FASTENING

THE ENHANCED ATTACHING

DESIGN MAKES THE LOCK

MOUNTING QUICK AND EASY.

DOUBLE MOUNTING SCREW

DESIGN PROVIDES A

STRONGER ATTACHING

FORCE.

ALARM CONTROLS CORPORATION

MAGNETIC

LOCKS ARE MANUFACTURED TO RIGID
STANDARDS AND ARE ASSEMBLED WITH THE
FINEST MATERIALS AND WORKMANSHIP.

ALL MAGNETIC LOCKS HAVE A LIMITED LIFETIME

WARRANTY, AND WILL BE REPAIRED OR 
REPLACED DUE TO DEFECTS IN MATERIAL
OR WORKMANSHIP.

THE 600 AND 1200 SERIES  MAGNETIC LOCKS

ARE U.L. AND CANADA U.L. LISTED. THE LOCKS        

CONFORM TO U.L. 10B, 10C FOR USE ON SWING-
ING TYPE FIRE DOORS AND CONVENTIONAL
DOORS. ALSO CLASSIFIED IN ACCORDANCE WITH
UNIFORM BUILDING CODE STANDARD 7-2, FIRE
TEST OF DOOR ASSEMBLIES. 

A COMPLETE LINE OF STANDARD AND CUSTOM

REQUEST TO EXIT STATIONS ARE AVAILABLE.  

IMPORTANT FEATURES

ALL MAGNETIC LOCKS HAVE A LIMITED LIFETIME
WARRANTY

MAGNETIC LOCKS ARE SUPPLIED WITH A THREAD  

LOCKING AGENT TO INSURE SECURE ATTACHMENT

MAGNETIC LOCKS ARE SUPPLIED WITH BOTH WOOD 
SCREWS AND SELF-TAPPING SHEET METAL SCREWS

ALL MAGNETIC LOCKS OPERATE ON 12 OR 24 VDC

ALL MAGNETIC LOCKS HAVE A LOW CURRENT DRAW

INSTANT RELEASE, NO RESIDULE MAGNETISM

ALL NON-ALIMINUM PARTS ARE PLATED

CLEAR ANODIZED US 28 FINISH STANDARD,

DURONIC US 40 FINISH AVAILABLE.

JBS-1 FOR 1200 SERIES,  JBS-2 FOR 600 SERIES 

SOUND LEVEL 80 db @ 3 FEET

MODULE REPLACES EXISTING CIRCUIT BOARD

VENTED COVER SUPPLIED 

MODEL           JBS-1/JBS-2

AUDIO INDICATOR MODULES

THIS MODULE WILL SOUND AS A MAGNETIC LOCK IS

BEING UN-LOCKED. AFTER POWER IS REMOVED FROM

LOCK,A THREE TO FIVE SECOND TONE WILL EMANATE

FROM THE MODULE INSIDE THE LOCK INDICATING

THAT THE LOCK IS UN-LOCKED. THIS MODULE WILL

OPERATE ON THE STANDARD TWO WIRE CONNECTION

TO THE LOCK. NO ADDITIONAL WIRING IS REQUIRED.

Содержание 1200LB

Страница 1: ...DC BI COLOR LED S P D T 3A RELAY CONTACTS SIGNALS A POWERED SECURELY SEALED DOOR CLEAR ANODIZED U S 28 FINISH STANDARD ALL NON ALUMINUM PARTS ARE PLATED ALARM CONTROLS CORPORATION 19 BRANDYWINE DRIVE...

Страница 2: ...MAGNETIC LOCK BY 5 8 LOWERS MAGNETIC LOCK BY 1 4 MODEL AM 3300 FOR 600 SERIES 1 W x 9 7 8 L MODEL AM 6300 FOR 1200 SERIES 1 1 2 W x 10 1 2 L MODEL AM 3305 FOR 600 SERIES 1 W x 9 7 8 L MODEL AM 6305 F...

Страница 3: ...0 SERIES 3 W x 8 1 4 L x 9 16 H MODEL AM 3325 FOR 600 SERIES MODEL AM 6325 FOR 1200 SERIES COMPRESSION MOUNTS ARMATURE ON FRAMLESS GLASS DOORS ACCOMODATES 60O AND 1200 SERIES FOR 600 AND 1200 SERIES M...

Страница 4: ...AL DOORS ALSO CLASSIFIED IN ACCORDANCE WITH UNIFORM BUILDING CODE STANDARD 7 2 FIRE TEST OF DOOR ASSEMBLIES A COMPLETE LINE OF STANDARD AND CUSTOM REQUEST TO EXIT STATIONS ARE AVAILABLE IMPORTANT FEAT...

Страница 5: ...KET HEADER PLATE 2 FOLD TEMPLATE ON DOTTED LINE TO FORM A 90 DEGREE ANGLE TAPE TEMPLATE AGAINST DOOR HEADER WITH DOOR IN A CLOSED POSITION 1 FROM DOOR FRAME OPPOSITE HINGE SIDE OF DOOR JAMB FOR A PAIR...

Страница 6: ...KET APPLY THE SCREW LOCKING AGENT TO THE ARMATURE BOLT DO NOT OVER TIGHTEN ARMATURE MUST ROCK TO ALIGN WITH THE MAGNET STEP 4 CLOSE THE DOOR AND ALIGN THE ARMATURE PLATE TO THE MAGNET AND APPLY POWER...

Страница 7: ...ANT BE APPLIED TO EACH SURFACE TO PREVENT RUST ALTHOUGH THE MATING SURFACES HAVE BEEN PLATED THIS ONLY NEEDS TO BE DONE WHEN DIRT BUILD UP IS NOTICED THE ARMATURE PLATE BOLT AND THE HEX HEAD SCREWS HO...

Страница 8: ...GA 18 GA 16 GA 14 GA 14 GA 12 GA 10 GA 12 GA 24 GA 24 GA 22 GA 22 GA 24 GA 24 GA 24 GA 24 GA PROBLEM CAUSE SOLUTION LOCK BUZZES INSUFFICIENT HOLDING FORCE DOOR DOES NOT LOCK DOOR STATUS SENSOR NOT WOR...

Страница 9: ...AGNET AND ARMATURE V V N O COM N C WHEN MOUNTING ARMATURE PLATE ON DOOR RUBBER WASHER MUST BE PLACED BETWEEN METAL WASHERS DO NOT EXCESSIVLY TIGHTEN SEX BOLT ARMATURE MUST FLOAT ON DOOR THREAD LOCKING...

Отзывы: