Reporting bit

Description

P

Normal activity

Q

Modem on line

R

Pings

V

Panel low battery

FCC compliance

Changes or modifications not expressly approved by Alarm.com can void the user’s authority to operate the equipment.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different form that which the receiver is connected

• Consult the dealer or an experienced radio/TV technician for help.

Operation is subject to the following two conditions:

• This device may not cause interference

• This device must accept any interference, including interference that may cause undesired operation of the device

This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your
body.

Regulatory Information

Listings

FCC ID: YL6-143450L, IC: 9111A-143450L

https://answers.alarm.com/ADC/Partner/Installation_and_Troubleshooting/Panels/Interlogix_Concord/Interlogix_Concord_Inst…

Updated: Wed, 04 Mar 2020 15:12:44 GMT

18

Содержание Knowledge Base Verizon VoLTE

Страница 1: ...liary 12 VDC power supply Status LEDs on the LTE module indicate bus and cellular network communications Compatibility The module can be used on Concord 4 0 and higher to enable Alarm com s interactiv...

Страница 2: ...sing Case color Belgian gray Case material High impact ABS plastic Main module components Components description Component Function PWR LED Indicates module power status https answers alarm com ADC Pa...

Страница 3: ...n MMCX antenna connectors The larger antenna connects to connector 1 the smaller antenna connects to connector 2 Module status LEDs Indicates communication with the LTE network report errors and signa...

Страница 4: ...ashes every time a data packet is received from the panel L3 LTE communication LED L3 flashes every time a data packet is received from the LTE radio L4 LTE signal level LED L4 flashes zero to five ti...

Страница 5: ...efore installation For more information see Account Creation 2 Turn off the Access Code Lock feature on the panel This feature must be off for the system to communicate with Alarm com 3 Installation i...

Страница 6: ...ly connect the GND and 12V terminals After two minutes LTE status LED L4 will flash between one and five times to indicate the LTE signal strength level where five is the strongest signal Note Alarm c...

Страница 7: ...proper operation Both antennas are pre installed for convenience The larger antenna will be connected to antenna connector 1 and the smaller antenna will be connected to antenna connector 2 3 For opti...

Страница 8: ...own in Figure 5 Note The module can also be powered off the SuperBus2000 two amp power supply 600 1019 but should not be powered directly off the panel Figure 5 Wiring Terminals 3 If required connect...

Страница 9: ...set to off for the system to communicate with Alarm com The module PWR LED should turn on After a few seconds the module BUS and AUTO LEDs should flash to indicate successful communication with the pa...

Страница 10: ...ered The yellow and green LEDs indicate the message status The top LED is not used Red LED On The module is in range and registered with the network Off The module is out of range and not registered w...

Страница 11: ...Blinks Blinks Module in range sending first message currently sending message 6 Blinks On Blinks Module out of range first message sent currently sending message 7 Blinks On Off Module out of range fi...

Страница 12: ...f the panel and re insert it If the error is still observed try a different module Finally if that does not fix the problem try a different panel 2 then 4 The module provisioning process could not be...

Страница 13: ...System Programming 0003 for module to communicate 8 If it persists the account may have been set up incorrectly Contact Alarm com Technical Support You will be asked to check the serial number of the...

Страница 14: ...st be deleted before it can join a new network LED L3 green or yellow L3 flashes with every communication between the module and its radio unit in Idle Mode and with every communication with Alarm com...

Страница 15: ...s The device you attempted to add into a Z Wave network was not successfully added 6 blink No Home ID present lasts until the module connects to Alarm com and is configured When the LTE module first c...

Страница 16: ...unication with panel L3 Communication with Alarm com L4 Alternates two seconds on then two seconds off L5 Inactive Troubleshooting Testing Tips Check LTE status LED L1 to see if it is flashing any err...

Страница 17: ...abled See Table 7 for a reference of the codes displayed Sensor 96 text Module serial number Table 7 Central Station Reporting Bits Reporting bit Description B Phone Test E Alarms F System trouble G S...

Страница 18: ...rning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation bet...

Страница 19: ...vice contains FCC ID RI7LE910SV IC 5131A LE910SV https answers alarm com ADC Partner Installation_and_Troubleshooting Panels Interlogix_Concord Interlogix_Concord_Inst Updated Wed 04 Mar 2020 15 12 44...

Отзывы: