Thermostat Z-Wave Specification
June 26, 2019
Building 36 Technologies
An Alarm.com Company
13
5.1.38
0x26 : Z-Wave Association Report Bit Mask
•
Bitmask to selectively enable non-required Z-Wave association reports. The report is
enabled if the bit is set to one (1).
o
Bit 0
–
Thermostat Mode
o
Bit 1 , 2
–
Reserved
o
Bit 3
–
Thermostat Operating State
o
Bit 4
–
Thermostat Fan Mode
o
Bit 5
–
Thermostat Fan State
o
Bit 6
–
Ambient Temperature
o
Bit 7
–
Relative Humidity
o
Bit 8
–
Reserved
o
Bit 9
–
Battery Low Notification
o
Bit 10
–
Battery Very Low Notification
o
Bit 11- Thermostat Supported Modes
o
Bit 12
–
Remote Enable Report
o
Bit 13
–
Humidity Control Operating State Report
o
Bit 14
–
HVAC Type
o
Bit 15
–
Number of Cool/Pump Stages
o
Bit 16
–
Number of Heat/Aux Stages
o
Bit 17
–
Relay Status
o
Bit 18
–
Power Source (C-Wire or Battery)
o
Bit 19
–
Notification Report Power Applied
o
Bit 20
–
Notification Report Mains Disconnected
o
Bit 21
–
Notification Report Mains Reconnected
o
Bit 22
–
Notification Report Replace Battery Soon
o
Bit 23
–
Notification Report Replace Battery Now
o
Bit 24
–
Notification Report System Hardware Failure
o
Bit 25
–
Notification Report System Software Failure
o
Bit 26
–
Notification Report System Hardware Failure with Code
o
Bit 27
–
Notification Report System Software Failure with Code
o
Bit 28
–
Display units (C/F)
o
Bit 29
–
Heat Fuel Type
o
Bit 30
–
Humidity Control Mode
o
Bit 31
–
Humidity Control Setpoints
•
Default is 0xFFFFFFFF
•
Size 4 byte