
English
3
Safety considerations
I UWATEC
®
Aladin
®
dive computers
• Avoid repeated ascents and descents (yo yo diving).
• Avoid repeated heavy workload while at depth.
• Plan the dives to be shorter if they are made in cold water.
• After finishing the decompression or at the end of a no-stop dive, the final stage of the ascent should
be as slow as possible.
• You MUST be familiar with all signs and symptoms of decompression sickness before using Aladin
®
PRIME
and Aladin
®
TEC
! Seek IMMEDIATE treatment for decompression sickness should any of these
signs or symptoms occur after a dive! There is a direct correlation between the effectiveness of treat-
ment and the delay between the onset of symptoms and the treatment for decompression sickness.
• Only dive with Nitrox after you have been thoroughly instructed by a recognised institution.
Repetitive dives
• Do not start your next dive before your CNS O
2
% status has dropped below 40%.
• Diving with Nitrox: Make sure your surface interval is long enough (just like diving with compressed
air). Plan for a minimum surface interval of two hours. Oxygen, too, needs sufficient time to leave the
body.
• Match gas mixture to the intended dive.
• Do not attempt a repetitive dive if the microbubble warning
is visible on the display.
• Plan a day without diving once a week.
• If you have to change computers, wait at least 48 hours before carrying out your next dive.
• Diving after a reset of the remaining saturation (reset, see page 41, or battery replacement, see
page 45) may lead you into potentially hazardous situations which could result in death or serious
injury. After a reset of the remaining saturation do not dive for at least 48 hours.
Altitude and diving
• Do not dive at altitudes higher than 4000m (13000 feet).
• After a dive do not rise to altitudes that Aladin
®
PRIME
or Aladin
®
TEC
prohibit via the
flashing altitude range number (see page 27).
Flying after diving
• After diving, wait at least 24 hours prior to flying.
NO
Aladin
®
PRIME
and Aladin
®
TEC
dive instruments are a personal protective equipment in compliance with
the essential safety requirements of the European Union directive 89/686/EEC. RINA SpA, Via Corsica 12,
I-16128 Genoa, notified body no. 0474, have certified the conformity with the European Standard EN
13319:2000.
EN13319:2000 Diving accessories - Depth gauges and combined depth and time measuring devices -
Functional and safety requirements, test methods. Any information on decompression obligation display-
ed by equipment covered by this standard is explicitly excluded from its scope.
I