Startup
467 774_a
15
3. Fix a pressure line
(Fig. B -12)
to the elbow
nipple
(Fig. B -13)
.
4. Open all closing off devices (valves, spray
nozzles, water cock) in the pressure line.
STARTUP
Filling the garden pump
CAUTION!
Dry running will destroy the pump! The
pump must be filled with water up to the
overflow before each use so that it can
draw water immediately.
1. Open the filling screw
(Fig. A -2)
with the filter
key.
2. Fill with water via the filling screw until the
marl on the pump housing is reached.
3. Screw the filling screw back in position.
ADVICE
In order to reduce the suction time, fill the
suction hose with water before screwing
in position.
Switch the pump on
1. Open all closing off devices (valve, spray
nozzle, water cock) in the pressure line.
2. Insert the mains plug on the connection cable
into the plug socket.
3. Switch the garden pump on at the on / off
switch.
CAUTION!
Do not allow the pump to run against a
closed off pressure line.
Switch pump off
1. Switch the garden pump off at the on / off
switch after use.
2. Close all the closing off devices in the pres-
sure line.
ADVICE
If nothing is drawn up for longer than
180 seconds, the garden pump automa-
tically switches to "Fault" and turns off.
CAUTION!
Danger of injury from hot water
In extended use against the closed pres-
sure side (>10 min.), the water in the
pump can be severely heated up and can
be emitted in an uncontrolled manner!
Isolate the unit from the mains and allow
the pump and water to cool down. Start
the unit again only after all the faults have
been rectified!
The risk of injury from hot water can arise if:
the installation is not correct
the pressure side is closed off
there is a lack of water in the suction line, or if
the pressure switch is defective.
Procedure
1. Isolate the unit from the mains and allow the
pump and water to cool down.
2. Check the unit, the installation and water le-
vel.
3. Start the unit again only after all the faults
have been rectified!
MAINTENANCE AND CARE
CAUTION!
The pump must be isolated from the
mains before any maintenance and ser-
vice work. Remove the mains plug from
the plug socket.
Clean the filter
1. Drain screw filter chamber
(Fig. A -10)
un-
screw the draining opening, drain the fil-
ter chamber and close the draining opening
again.
2. Unscrew clear sight cover filter
(Fig. A -9)
using the filter key
(Fig. C -18/D)
.
3. Remove filter
(Fig. C -20)
from the filter hou-
sing and clean under flowing water.
4. Clean the filter housing and clear sight cover
of the filter.
5. Before fitting the filter, check the filter seals
(Fig. C -19)
and the housing seal
(Fig. C -23)
and replace if necessary.
6. Fit the filter, screw the clear sight cover in
place and tighten hand-tight with the filter key.