3.  Cleaning 

 

3.1 Preparation for cleaning 
 

  Please switch off the appliance first and disconnect the mains plug before cleaning 

the humidifier. 
 

  Open the upper lid of the humidifier and first remove the white water tank and the 

black steam nozzle shaft incl. steam nozzle. 
 

  Now unscrew the residual water drain (see illustration on the right), which is 

located on the lower rear side, and empty the appliance completely of any residual 
water. 
Note: It is best to place the appliance in a sink to empty it, as up to one litre of 
residual water can still run off ! 

 

3.2 Cleaning the housing and the wet area 
 

  Only use mild cleaning agents to clean your humidifier. 

 

  Rinse the white water tank carefully and wipe it from the outside with a damp cloth. 

 

  Next, clean the black steam nozzle shaft incl. the steam nozzle. 

 

  Now carefully clean the white water cup incl. the ultrasonic water vapour unit in the lower part of your machine. 

 

Notes: In the case of hard water (the tap water contains too much calcium and magnesium), limescale deposits 
can occur in the humidifier and especially in the water cup. These limescale deposits in the unit and especially 
in the area of the evaporator and the water vapour unit can lead to impaired functioning. We therefore 
recommend that you 

 

Clean the evaporator and the ultrasonic water vapour unit every week. 

 

Change the water in the water tank regularly to keep it fresh. 
 

The ultrasonic water vapour unit itself is made of silver metal and has three approx. 2 cm large evaporators 
(eyes) on the top. 

 

a.)  Add 5-10 drops of a suitable cleaning agent (e.g. Dimanin A* 

available in any pharmacy*

) to the surface of 

the vaporisers or also to the remaining area of the water cup and wait a few minutes. 

b.)  Then carefully wipe off any flakes of dirt (limescale) from the 

surfaces with a soft sponge or the enclosed brush (see 
illustration on the right). 
Note: Never clean the evaporators with objects made of metal 
or blunt material! This would damage the evaporators. 

c.)  Finally, rinse the evaporator / water cup well with clear water. 
 

  With the exception of the electrical control panel, all parts of the 

humidifier can be wiped or cleaned with a soft damp cloth when the 
unit is switched off. 

 

  Remove any water, clean the unit thoroughly and dry it well if you are not going to use the humidifier for a long 

time. 

 

 
 
 
 
 
 
 
 
 

Содержание WDH-MG1

Страница 1: ...If despite the greatest possible care there should ever be cause for complaint please contact us briefly as we are very concerned about your satisfaction and would like to clear up any misunderstandi...

Страница 2: ...g time switch it off and disconnect the mains plug Do not start the appliance without water in the water tank Do not use the unit in bathrooms or other places with very high humidity Do not add any ad...

Страница 3: ...dgau Germany www AKTOBIS de Email Info Aktobis de Device description Front Back With open lid Control panel Inspection flap Carrying handle Steam nozzle Cover Steam nozzle Residual water drain Main sw...

Страница 4: ...ing options are available L Lowest target humidity value below 25 Not recommended 25 30 35 40 45 50 55 60 65 70 75 80 85 H Highest target humidity value over 85 not recommended The unit humidifies unt...

Страница 5: ...fore use Carefully remove the humidifier from its packaging box and remove all protective packaging Place the humidifier on a firm flat surface that provides sufficient space for the unit and the user...

Страница 6: ...deposits can occur in the humidifier and especially in the water cup These limescale deposits in the unit and especially in the area of the evaporator and the water vapour unit can lead to impaired f...

Страница 7: ...strength lights up but no steam is emitted No water in the water tank Fill up the water tank Abnormal smell New device Remove the water tank open the lid and leave the tank in a cool place for approx...

Страница 8: ...ed due to the lack of fluid loss through sweating This is due to the humidification of the dry inhaled air and the associated loss of water If the cold outside air is heated during inhalation its wate...

Страница 9: ...lly dismantled units Conformity The humidifier has been tested and itself and or parts thereof have been manufactured under the following safety standards GS tested by Intertek and of course with CE L...

Страница 10: ..._________________________________________________________ _________________________________________________________ _________________________________________________________ __________________________...

Отзывы: