Important operating and safety instructions regarding the refrigerant R290 in this unit: 

 

 

Read these instructions carefully and observe them strictly ! 

 

The unit operates with the refrigerant R290. This refrigerant is highly flammable and explosive if the safety 
instructions are not observed! 

 

The unit should not be stored or operated in a room with burning/heating appliances or open fire ! 

 

Please note that the refrigerant is odourless and therefore a leak cannot be detected immediately by an 
emerging odour ! 

 

Make sure that the outlet of the exhaust air is always ensured and not obstructed by other objects ! 

 

Ensure a minimum distance of at least 50 cm from open flames and heating elements ! 

 

Set-up, operation and storage of the unit should take place in a room with a minimum size of 10 

m2 

 

When cleaning, proceed strictly according to the manufacturer's instructions and do not use any additional heat 
sources to possibly accelerate the defrosting process of the appliance ! 

 

This unit has parts that must not be replaced or repaired ! 

 

The refrigerant cannot be renewed or replaced ! 

 

Do not carry out any independent repairs or modifications to your unit ! 

 
 

 

 

 
 

Description of the unit parts: 
 

 

 
 
 

Supply air 

Transport handle 

Air filter 

screen 

Condensation tank 

Wheels 

Main switch ( I / O ) 

Electricity consumption 

meter 

"Tank Full" 

Signal 

Hose connection 

Feet 

Содержание WDH-35B

Страница 1: ...t To ensure that you get a lot of enjoyment from this product here are a few more tips In case of any problems We hope that the unit meets your expectations If despite the greatest possible care there...

Страница 2: ...it points diagonally backwards and the four fastening holes of the handle are above the fastening holes on the unit casing See the cover picture of the operating instructions Then screw in the four h...

Страница 3: ...otherwise it can lead to a reduction in performance and in the worst case to overheating and or fire Please always keep a distance of approx 20 cm to the wall to avoid possible overheating of the uni...

Страница 4: ...e outlet of the exhaust air is always ensured and not obstructed by other objects Ensure a minimum distance of at least 50 cm from open flames and heating elements Set up operation and storage of the...

Страница 5: ...ore you press the main switch I O again In case of cold ambient temperatures or icing in the unit a sensor automatically controls a defrosting process Meanwhile the defrost mode automatically controls...

Страница 6: ...sometimes even be the case daily on dusty construction sites Switch off the unit and disconnect the mains plug Now remove the air filter screen by pulling it upwards by the tab Wash the dirty sieve w...

Страница 7: ...fication table for DURABLE OPERATION 35 degrees and 90 RH approx 40 litres optimum or maximum capacity 30 degrees and 80 r h approx 35 litres and at 60 r h approx 18 litres 20 degrees and 80 r h appro...

Страница 8: ...ng to EN 55014 1 2017 EN 55014 2 2015 EN 61000 3 2 2014 EN 61000 3 3 2013 Correct disposal of this product Within the EU this symbol indicates that this product should not be disposed of with househol...