![AKO AKO-15626 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/ako/ako-15626/ako-15626_quick-manual_2886513022.webp)
Pushbutton assembly
The pushbutton should be installed inside the
cold room store, in a visible place and no higher
than 125 cm from the floor.
AKO-520622
Secure it to the wall through the holes
designed for this purpose (A), connect it to the
device following the wiring diagram and close
the cover using the screws included (B).
A gland is included for cables with a Ø of 6 to
12 mm
Recommended installation
The cable must make a
180º bend
after
exiting from the bottom of the button case (as
seen in image) to prevent water from reaching
cables.
7.- Wiring
Trapped person in cold room store pushbutton
(Only AKO-15627 / AKO-15646)
B
B
A
A
180º
1 2 3 4 5 6 7 8 9
10 11
P1 P2 P3
12
13
15
17
14
16
18
PUSHBUTTON
AKO-15627
AKO-15646
Bridge necessary
Cable not
included
Max.
100 mts
+12Vcc
GND
22