[AKD4753-A]
1-4-1. Parameter Setting
(1) Please set a parameter of each Filter.
Parameter Function
Setting
Range
Sampling Rate
Sampling frequency (fs)
7350Hz
≤
fs
≤
48000Hz
HPF
Cut Off Frequency
1.042x10
-3
≤
fc/fs
≤
0.24
High pass filter cut off frequency
LPF
Cut Off Frequency
Low pass filter cut off frequency
5.208x10
-3
≤
fc/fs
≤
0.24
5 Band Equalizer
EQ1-5 Center Frequency
EQ1-5 Center Frequency
3.125x10
-3
≤
fon/fs < 0.4969
EQ1-5 Band Width
fbn/fs
≤
0.25
EQ1-5 Band Width
)
(
EQ1-5 Gain
-1
≤
Gain < 3
EQ1-5 Gain
)
(
Table 6. Parameter Setting
Note 1. A gain difference is a bandwidth of 3dB from center frequency.
Note 2. When a gain is smaller than 0 , EQ becomes a notch filter.
(2) “HPF LPF Enable” , “HPF” ,”LPF” , “EQ1”, “EQ2”, “EQ3”, “EQ4”, “EQ5”
Please set ON/OFF of Filter with a check button. When checked it, Filter becomes ON.
When “Notch Filter Auto Correction” is checked, perform automatic correction of the center frequency
of the notch filter is executed.
Figure 24. Filter ON/OFF setting button