Version: 1.0 

 

   

 
 

No  Description 

Qty 

1  Wall mounting frame 

2  Rear case 

3  Evaporator pipe cover 

4  Drainage pipe 

5  Pipe clamp 

6  Cross flow fan 

7  Fan bearing 

8  Ring of bearing 

9  Water tray 

10  Swing louver 

12 

11  Swing link 

12  Manual lever 

13  Evaporator assy 

14  Evaporator support 

15  Front case 

16  Screw cover 

17  Front panel 

18  Filter   

19  Air cleaner holder 

20  Guide louver 

21  Remote controller Y512F 

22  Guide louver bearing 

23  Main PCB 

24  Fuse 3.15A250VAC 

25  Room sensor 

26  Tube sensor 

27  Sensor insert 

28  Sensor motor MP28EA 

29  Motor FN7C 

30  Motor clamp 

31  Wire clip 

32  Wire clamp 

33  LED holder 

34  Receiver board JD 

35  Receiver board K 

36  Terminal board T240A 

37  Electric box cover 

38  Electric box 

39  Transformer SC23B 

40    Connecting cable 

41  Power cord 

42  Signal control wire 

 
 
 
 
 
 
 
 
 
 
 
 

Все каталоги и инструкции здесь:

 http

:

//splitoff.ru/tehn-doc.html

Содержание AC-S7CG

Страница 1: ...Air Conditioner Service Manual Большая библиотека технической документации http splitoff ru tehn doc html каталоги инструкции сервисные мануалы схемы ...

Страница 2: ...2 Model No AC S7CG Version 1 0 MODEL AC S7CG Все каталоги и инструкции здесь http splitoff ru tehn doc html ...

Страница 3: ... No AC S7CG Version 1 0 CONTENTS TECHNICAL SPECIFICATION 4 PERFORMANCE CURVE 5 EXPLODED VIEW PARTLIST 8 CIRCUIT DIAGRAM 12 PCB FUNCTION MANUAL 13 Все каталоги и инструкции здесь http splitoff ru tehn doc html ...

Страница 4: ... CFM Hi M3 H 400 Air Flow control Remarks Ventilation No Exhaust No Energy saver switch No Dimension W x H x D mm indoor 740 x 250 x 180 Dimension W x H x D mm outdoor 660 x 428 x 255 Packing Dimension W x H x D mm indoor 870 x 336 x 280 Packing Dimensions W x H x D mm outdoor 765 x 500 x 350 Indoor Weight net Gross kg 8 11 Outdoor Weight Net Gross kg 25 29 Все каталоги и инструкции здесь http spl...

Страница 5: ...etween low pressure operation current and temp Cooling operation condition In testing indoor and outdoor have same work condition Heating operation Indoor work condition dry bulb temp 21 wet bulb temp 15 5 o C Все каталоги и инструкции здесь http splitoff ru tehn doc html ...

Страница 6: ...6 Model No AC S7CG Version 1 0 Все каталоги и инструкции здесь http splitoff ru tehn doc html ...

Страница 7: ...7 Model No AC S7CG Version 1 0 Все каталоги и инструкции здесь http splitoff ru tehn doc html ...

Страница 8: ...8 Model No AC S7CG Version 1 0 EXPLODED VIEW PART LIST INDOOR UNIT Все каталоги и инструкции здесь http splitoff ru tehn doc html ...

Страница 9: ... 18 Filter 2 19 Air cleaner holder 2 20 Guide louver 1 21 Remote controller Y512F 1 22 Guide louver bearing 3 23 Main PCB 1 24 Fuse 3 15A250VAC 1 25 Room sensor 1 26 Tube sensor 1 27 Sensor insert 1 28 Sensor motor MP28EA 1 29 Motor FN7C 1 30 Motor clamp 1 31 Wire clip 1 32 Wire clamp 1 33 LED holder 1 34 Receiver board JD 1 35 Receiver board K 1 36 Terminal board T240A 1 37 Electric box cover 1 3...

Страница 10: ...10 Model No AC S7CG Version 1 0 OUTDOOR UNIT Все каталоги и инструкции здесь http splitoff ru tehn doc html ...

Страница 11: ... Compressor KH145VFRA 1 10 Overload protector 1 11 Handle 1 12 Gas valve 1 13 Liquid valve 1 14 Valve support 1 15 Right side plate 1 16 Wiring clamp plate 1 17 Wiring clamp cover 1 18 Terminal board T386A 1 19 Electric plate 1 20 Comp capacitor 1 21 Capacitor clamp 1 22 Fan capacitor 1 23 Isolation sheet assy 1 24 Condenser assy 1 25 Rear grill 1 Все каталоги и инструкции здесь http splitoff ru t...

Страница 12: ... No AC S7CG Version 1 0 CIRCUIT DIAGRAM These circuit diagrams are subject to change without notice Please refer to the ones stuck on the machines Все каталоги и инструкции здесь http splitoff ru tehn doc html ...

Страница 13: ... keep the previous state 2 In this mode the reversing valve is inactive the temp setting range is from 16 30o C 3 Protect function a Anti freezing function i If compressor have run 6 minutes and detect T eva 0o C for continuous 3 minutes then the compressor outdoor fan stopped indoor fan run at the set fan speed After 3 minutes later it will run at the original state if T eva or 10o C b Compressor...

Страница 14: ...ing state 2 In this mode the temperature setting range is 16 30o C 3 The working conditions of auxiliary electric heater a In heating mode when compressor is working indoor motor runs at high speed and middle speed If it detect T eva 50o C for continuous 8 seconds and T indoor or 25o C electric heater will work if compressor stop or indoor motor runs at low speed or T eva 54o C or T indoor 28o C o...

Страница 15: ...standard heating T set 20o C 2 Working procedures a If T indoor or T set 1o C select cooling mode from this time the set temp is 25o C If T indoor or T set 1o C compressor and outdoor motor stop indoor motor runs at the set speed if T set 1 T indoor T set 1o C keep the original state b If T indoor or T set 2o C select heating mode from this time the set temp is 20o C if T indoor or T set 4o C comp...

Страница 16: ...IR on the remote controller to select fresh air 1 function the swing motor keeps running till you give a signal to change it 6 Automatic fan speed a In cooling mode if T indoor T set 5o C high speed T indoor or T set 3o C middle speed T indoor or T set 1o C low speed b In dehumidify mode if T indoor or T set 5o C high speed T indoor or T set 2o C low speed SLEEP mode 1 In cooling or dehumidifying ...

Страница 17: ...Большая библиотека технической документации http splitoff ru tehn doc html каталоги инструкции сервисные мануалы схемы ...

Отзывы: